USER PARAMETERS
31
Chapter 8
To access the percentage adjustment of pellet feeding, enter the user programming by pressing key 3 and,
holding this down, press key 5.
At this point use key 5 to move within the menu until “
UT F
” appears on display D2.
If, inadvertently, progress is made beyond this parameter, exit using key 1 and repeat the operation.
The value “
00
” will appear on display D1: keys 2 and 3 can be used to adjust the percentage increase/
decrease desired by 5 points per time (the parameter can be varied with a maximum travel from –50 to
+50).
Adjustment table
LACK OF
FUEL
Increase the percentage value by 5 points and try the
stove with the new calibration for at least half an hour.
If the problem is attenuated, but not solved, increase by
another 5 points. Repeat the operation until the problem
is solved. If the problem cannot be resolved, contact the
after-sales service.
EXCESS
FUEL
Decrease the percentage value by 5 points and try the
stove with the new calibration for at least half an hour. If
the problem is attenuated, but not solved, decrease by
another 5 points. Repeat the operation until the problem
is solved. If the problem cannot be resolved, contact the
after-sales service.
When the adjustment has been made, press button 1 to conform and escape.