PRODUCT FUNCTIONALITY
19
Chapter 5
IGNITION
Before switching the stove on, the following points must be verifi ed:
1.
a. the feed-box must be full of pellets
b. the combustion chamber must be clean
c. the pot must be completely free and clean
d. check the hermetic closure of the fi re door and the ash drawer
e. make sure the power supply cable is connected correctly
f. the bipolar switch in the rear right part must be positioned on 1
Press button 1 for 3 seconds: display D1 will show “
2.
START
”, while on display D2, starting from
number 8, the numbers will decrease every second. In this phase the appliance performs self-analysis
to check the functionality of each individual electric component. When this cycle has been completed,
display D1 will show “
IGNITION
”, while display will show “15” (these are the minutes when the stove
attempts the ignition phase and decreases by 1 every minute that passes). NOTE: The fi rst time the
product is used, even if the feed-box is full, there is the possibility that the pellets are not distributed
into the combustion chamber for the fi rst 15 minutes. This is because the pellet feed worm screw is
empty. If no fl ame has developed in the stove after 15 minutes D1 will show “
IGNITION FAILURE
”.
If points 1 and 2 have been performed correctly, when the fl ame is developed the stove will pass to
“
START
” mode.
On termination of the start phase the stove will pass to normal functioning: display D1 will show the
3.
room temperature while display D2 will show the work power.
ATTENTION!!!
1. DO NOT USE ANY INFLAMMABLE LIQUIDS FOR IGNITION
2. DO NOT ALLOW THE BAG OF PELLETS TO COME INTO CONTACT WITH THE BOILING HOT STOVE
DURING THE FILLING PHASE
N.B. In the case of continuous ignition failure, contact an authorised technician.
STOVE FUNCTIONING
NORMAL FUNCTIONING
When ignition has taken place, the user can adjust the heating power using buttons 4 and 5. By pressing
button 4 the heat power is decreased and therefore also the consumption of pellets per hour, vice versa by
pressing 5, the heating power is increased and as a consequence also pellet consumption. As well as the
adjustment of fl ow rate it is also possible to adjust the room temperature directly from the control board.
Regarding the ventilation of hot air the stove adjusts itself automatically.
Check the content of the feed-box in order to prevent the fi re going out due to the lack of fuel.