CLEANING
33
Chapter 9
CLEANING THE HEAT EXCHANGER (Monthly)
4.
The heat exchangers chamber must be cleaned every month as the
soot deposited on the rear of the cast iron hearth wall blocks the
regular fl ow of fumes.
To access the heat exchangers, remove the central piece from the
hearth wall, following the operations described below:
Remove the pot from its location
Turn the lockbolt by 180°.
Take the extractable cast iron and turn it downwards.
Finally, slide it from the combustion chamber by pulling it towards
yourself, paying attention to the 2 lateral cast iron hooks below.
Once the heat exchanger compartment can be accessed use the
supplied fi re irons to remove and scrape the soot deposited and
only then use the suction device to completely remove the ash.
When cleaning has been completed, re-position the extractable
cast iron with the opposite movement used to remove it. When the
hearth wall has been positioned, turn the lockbolt by 189° to take it
to its original position.
DOOR, ASH DRAWER AND POT GASKETS
5.
The gaskets guarantee the tightness of the stove and its consequent good functioning.
These must be checked regularly: if they should be worn or damages they must be replaced immediately.
These operations must be carried out by a qualifi ed technician.
N.B. For correct functioning, the stove must undergo routine maintenance by a qualifi ed technician, at
least once a year.
If the power supply cable is damaged, it must be replaced by the after-sales service or by a similarly qualifi ed
person, so as to avoid al risks.
CONNECTION TO THE FLUE
Suck and clean the pipe that leads to the fl ue yearly or anytime that it is necessary. If there are horizontal
tracts the residues must be removed before they can obstruct fl ue passage.
NON-CLEANING jeopardises
safety.
fi gure 9.6