9
SAFETY DEVICES
Chapter 3
SAFETY DEVICES
WARM AIR BLOWER BREAKDOWN
If the blower stops for any reason, the stove automatically shuts down to prevent overheating.
FUME EXHAUSTER BREAKDOWN
If the exhauster stops, the electronic unit immediately prevents pellet feeding.
PELLET FEED MOTOR BREAKDOWN
If the motor stops, the stove continues to operate until the minimum cooling level is reached.
IGNITION FAILURE
If a fl ame is not developed during the ignition phase, the appliance automatically attempts ignition again,
this time without pellet feeding.
If no fl ame develops also in this case, the appliance will signal “
IGNITION FAILURE
” on the display. When
trying to re-ignite the machine, it will indicate “
WAIT FOR COOL
.” on the display.
This function reminds
that before performing ignition, it must be ensured that the pot is completely free and clean
.
TEMPORARY POWER FAILURE
The appliance will re-light automatically after a brief power failure. When the power goes off , the stove
may emit a minute quantity of smoke inside the house for a period of 3 to 5 minutes.
THIS DOES NOT POSE ANY SAFETY RISK.
ELECTRICAL SAFETY
The stove is protected against violent power swings by a master fuse on the rear of the stove (2A 250V
delayed).
EXHAUST FUME SAFETY
If the exhaust system fails, an electronic pressure switch stops the stove and an alarm is signalled.
PELLET OVERHEATING SAFETY
In case of overheating inside the pellet hopper, this safety device blocks stove operation; resetting is
manual and must be performed by an authorized technician.