SSE232-LE User’s Manual
Exemys
A.3. Default
Configuration
This is the factory default configuration.
Table 13 - Default Configuration
Parameter
Value
IP
0.0.0.0 (DHCP)
Netmask
0.0.0.0
Gateway
0.0.0.0
Protocol
TCP
Automatic Reset
Enabled
Web Configuration
Enabled
Digital Input Report
Disabled
Remote Configuration Password
None
Baud Rate
9600
Parity
None
Data Bits
8 bits
End char
Disabled
Window of time
Disabled (0ms)
Mode
Server
Listen Port (Server Mode)
1000
Server IP Address (Client Mode)
192.168.0.99
IP Port Server Number (Client Mode)
1000
Inactivity Timeout
Disabled
COM Type
Depends on the SSE232-LE model
A.4. Connectors
Pinout
Rx + (1)
Rx - (2)
Tx + (3)
Tx - (6)
1
8
13 12 11 10 9 8 7 6 5 4 3 2 1
25 24 23 22 21 20 19 18 17 16 15 14
Tx
(in)
Rx
(out)
RTS
(in)
CTS
(out)
GND
TR+
TR-
R+
R-
NC NC NC NC NC
NC
NC NC NC
NC NC NC NC
NC = NO CONNECT
DCD
(out)
DSR
(out)
DTR
(in)
DB25 Female Connector DCE
Ethernet Connector
Figure 13 - Connectors Pinout
www.exemys.com Rev.
1.0.3
Page30