SSE232-LE User’s Manual
Exemys
3.1.5 Configuration of Network Basic Parameters through the console
Once you access the console, you can change the network configuration parameters with the
following commands:
IP
,
NETMASK
, and
GATEWAY
. If you want to change the SSE232-LE IP
address, Netmask and / or Gateway, you can enter the commands to modify these parameters.
But then you must enter the
END
command so the changes take effect. When the
END
command
is executed, SSE232-LE will detect that any of these three basic parameters has been changed
and the system will be restarted. If the console is run from a Telnet session, the communication
with the equipment will be interrupted. You must reopen the TCP session using the new IP
address.
To change the IP address, enter the following command:
>ip:192.168.0.110
Ok, IP Address 192.168.0.110
NOTICE, This parameter will be accepted upon execution of the END command.
At that moment, communication with the equipment will be interrupted.
If you are not sure, close communication without typing the END command.
>_
To change the netmask, enter the following command:
>netmask:255.255.255.0
Ok, Netmask 255.255.255.0
NOTICE, This parameter will be accepted upon execution of the END command.
At that moment, communication with the equipment will be interrupted.
If you are not sure, close communication without typing the END command.
>_
You can change the Gateway using the gateway command. Enter the following command:
>gateway:192.168.0.200
Ok, Gateway 192.168.0.200
NOTICE, This parameter will be accepted upon execution of the END command.
At that moment, communication with the equipment will be interrupted.
If you are not sure, close communication without typing the END command.
>_
Enter the END command for SSE232-LE to accept the network parameter changes. You will
lose communication with the equipment if the commands were entered from the TCP
console.
3.2 Operation
3.2.1 Introduction
In SSE232-LE, each COM (A, B, C o D) corresponds to a TCP socket. Thus, once communication
with any of these sockets is established, information will be transparently transferred from the
corresponding COM to the socket and vice versa.