background image

Manual UVC Air Sanitizer V1000E

 

 

13.11.2020 

Page 

7

 of 

33

 

Risk of injuries by UVC light.  

  Protection objective: Prevent personal injuries by UVC light 

  UVC light is harmful for eyes and skin of humans or animals. It can cause serious 

accidents, burn the human skin and cause significant skin irritation. UVC light can cause 
serious injuries to the human eye.  

  When opening the housing of the Air Sanitizer while it is operating, the UVC light will be 

exposed and leave the housing. This endangers all surrounding persons. The housing 
shall only be opened when the device is turned off and disconnected from mains power. 

Risk of injuries by UVC light.  

  Protection objective: Prevent personal injuries by UVC light 

  UVC light is harmful for eyes and skin of humans or animals. It can cause serious 

accidents and burn the human skin and cause significant skin irritation. UVC light can 
cause serious injuries of the human eye.  

  During operation a certain amount of UVC light is emitted out of the housing. Only 

persons are harmed that are very close to the device and that are staring at the device 
for several hours. 

Risk of injuries by UVC light.  

  Protection objective: Prevent personal injuries by UVC light 

  UVC light is harmful for eyes and skin of humans or animals. It can cause serious 

accidents and burn the human skin and cause significant skin irritation. UVC light can 
cause serious injury. UVC light is harmful for eyes and skin of human or animals.  

  When the housing of the Air Sanitizer is damaged and still being operated the UVC light 

might be exposed and leave the housing. This endangers all surrounding persons. If the 
housing is damaged the product shall no longer be operated. Qualified persons should 
disconnect the device from power supply and contact service partner. Persons 
approaching the faulty device should wear appropriate personal safety equipment such 
as face shield, clothes, gloves etc.  

Risk of injuries by UVC light.  

  Protection objective: Prevent personal injuries by UVC light. 

  UVC light is harmful for eyes and skin of humans or animals. It can cause serious 

accidents and burn the human skin and cause significant skin irritation. UVC light can 
cause serious injury. UVC light is harmful for eyes and skin of human or animals.  

  The light traps, clamping rings and cover rings (see figure  

Figure 9) must always be mounted when the device is turned on, it additionally protects 
against the UVC light rest radiation that escapes out of the housing. 

Risk of injuries by breathing in mercury vapor.  

  Protection objective: Prevent personal injuries by mercury vapor 

  If a UVC tube is broken, the encapsulated mercury will be exposed to the air. Breathing 

in mercury vapor is dangerous for the human body as mercury is toxic. This endangers 
all surrounding persons. 

  If a UVC tube is broken, the room should be ventilated immediately and everyone should 

leave it until the broken glass and other parts have been properly disposed of outside of 
closed rooms and the room has been adequately ventilated 

Risk of injury or death by electrical shock. 

  Protection objective: Prevent personal injuries or death 

  If the housing of the device is opened, persons who work on the device can touch parts 

that can cause an electrical shock. 

  Always disconnect power supply before working on the device or opening the housing. 

Working on the device and opening the housing should only be done by fully qualified 
personnel. Follow local laws and regulations. 

Содержание V1000E

Страница 1: ...Manual Version 1 1 Date Revision No Author Checked Description 20 10 2020 1 0 GJN TSN TNR DRD Version 1 0 13 11 2020 1 1 TSN GJN Version 1 1 Contact Tel 49 2204 9485 30 E Mail info exactsolutions de W...

Страница 2: ...ration 11 6 2 Positioning and dimensioning 12 6 3 Mechanical setup 13 6 4 Electrical setup 15 6 5 Operation 16 6 5 1 Operation with multifunctional switch 16 6 5 2 Operating via network 18 6 6 Periodi...

Страница 3: ...oped and manufactured with the highest care and attention However improper handling can cause a risk for safety and or damage Read these instructions carefully before handling and installing the produ...

Страница 4: ...Electrical work shall only be done by a fully qualified and trained electrician Follow the local laws and regulations Warning UVC radiation open the housing only when the device is disconnected from...

Страница 5: ...ctrical shock fire malfunction or deformation may occur Keep the packing anti moisture material or vinyl packing out of the reach of children This material is harmful if swallowed Vinyl packing can ca...

Страница 6: ...etc Otherwise parts or the whole system may fall down Protection objective prevent personal injury or property damage Only use correct mounting material such as screws screw anchor etc depending on th...

Страница 7: ...housing is damaged the product shall no longer be operated Qualified persons should disconnect the device from power supply and contact service partner Persons approaching the faulty device should wea...

Страница 8: ...that are protected by a Residual Current Device RCD Risk of injury product damage or incorrect functionality Protection objective prevent personal injury product damage and incorrect functionality Us...

Страница 9: ...held measurement device Model number ASZ UVCSafe UVpro Safe is a measuring instrument to determine a potential UV C exposure at the workplace Based on directive 2006 25 EC the UVpro Safe measures the...

Страница 10: ...ely on the installation and positioning We or our partners would be happy to advise you if you have any questions 5 2 Specifications Parameter Value UVpro tubes 6 x 41 W Total UVC output W 253 7 nm 72...

Страница 11: ...with an intact cable Check cables and connectors before installation The V1000E weights around 29kg Any handling of the devices must be carried out by at least two people Additional people may have to...

Страница 12: ...s to be installed in such a way that the air outlet points towards the main part of the room For multiple air sanitizer these should be uniformly distributed in the room Inlets and outlets should alwa...

Страница 13: ...the device Figure 3 Top view M8 threads for installation marked in red Figure 4 Bottom view M8 threads for installation marked in red WARNING Make sure to use correct mounting material to fix the moun...

Страница 14: ...13 11 2020 Page 14 of 33 Figure 5 Don t use threads of tension ring WARNING Do not use the threads of the tension ring to hang or secure the V1000E Please consult local laws and regulations regarding...

Страница 15: ...ts against the UVC light rest radiation that escapes out of the housing WARNING This product is a device of protection class 1 and require a protective earth grounding and may only be connected to cir...

Страница 16: ...etects the right fan speed measurement interval approx 10 20sec If the correct fan speed is detected the indicator will switch to green light still blinking slowly Push the button again the V1000E wil...

Страница 17: ...slowly red max 20sec Device 50 fan speed fan speed is measured system ok continuously red all the time Device 100 fan speed failure in system one or more lamps are not running blinking red all the ti...

Страница 18: ...off UVC tubes on or off Fans on or off Fan speed in percentage UVC tubes operating time UVC tubes alarm Fan alarm Fan speed in rpm Tube current as relative value Serial Number as string Firmware setFa...

Страница 19: ...etup with the following syntax IP Address command param Example A 192 168 000 010 setFanSpeed 50 Reply fanspeedPct 50 Example B 192 168 000 010 state Reply power 1 stateTubes 1 stateFans 1 fanspeedPct...

Страница 20: ...regular visual inspection of the quartz tube and the reflectors for dust and deposits should be carried out The right time depends on the air purity If you are installing in a new location check more...

Страница 21: ...C Air Sanitizer V1000E 13 11 2020 Page 21 of 33 7 3 Replacing UVC tubes Only clean the device with a soft cloth Clean the light traps with a vacuum cleaner or with a soft cloth Do not rinse or immerse...

Страница 22: ...ried out by qualified persons WARNING Always disconnect the device from the power supply while you are working on the device WARNING Wear gloves when replacing the tubes to protect yourself and the tu...

Страница 23: ...e tube must be replaced The fan has failed or is vibrating loudly The fan is defect or the power supply to the fan is interrupted The fan is covered with dirt dust The device must be repaired by the m...

Страница 24: ...UVC tubes have a limited life time They are subject to a continuous aging process The life time of the UVC tubes is 12 000 hours under normal operating conditions power drop 25 5 compared to the nomi...

Страница 25: ...four screws on the top and bottom 3 Gently remove the light trap 4 Gently remove the metal mesh filter 5 Clean the metal mesh filter with a vacuum cleaner from both sides If there are holes in the fil...

Страница 26: ...ring is tight enough around the cover ring and around the raised edge of the pipe so that the parts are connected securely Each of those screws are additionally secured with a self locking nut Make su...

Страница 27: ...tubes To protect your eyes wear safety glasses or a face shield 7 3 1 Removing old tubes 1 Open the light trap at the air inlet side by removing the screws on the top and bottom 2 Gently remove the l...

Страница 28: ...at ceramic end of UVC tube 6 Move the tube gently out of the V1000E reaction chamber The tube will easily slide out of the holding clamp 7 Remove the coupling ring and the rubber seal from the old tub...

Страница 29: ...is positioned correctly Figure 15 Figure 15 Socket guidance segment and 4 connecting pins 3 Carefully insert the four pin contacts into the corresponding openings in the base at the front possibly wi...

Страница 30: ...0sec 8 Disposal of components 8 1 UVC tube Like fluorescent lamps UVC tubes should be disposed of as hazardous waste as they contain mercury There are also free collection points in your area where yo...

Страница 31: ...Manual UVC Air Sanitizer V1000E 13 11 2020 Page 31 of 33 9 Mechanical Drawing...

Страница 32: ...Manual UVC Air Sanitizer V1000E 13 11 2020 Page 32 of 33 10 Declaration of conformity...

Страница 33: ...ual UVC Air Sanitizer V1000E 13 11 2020 Page 33 of 33 Imprint EXACT solutions GmbH Lustheide 85 51427 Bergisch Gladbach GERMANY Tel 49 2204 9485 30 E Mail info exactsolutions de Web www exactsolutions...

Отзывы: