Manual UVC Air Sanitizer V1000E
13.11.2020
Page
8
of
33
Risk of injury or death by electrical shock.
•
Protection objective: Prevent personal injuries or death
•
If the housing of the device is damaged, deformed etc. there is an increased risk that the
inside is also damaged. Persons who touch the housing might get an electrical shock.
This endangers all persons who might touch a damaged product.
•
When there is any damage, disconnect power supply of the device by qualified
personnel. Contact vendor / service partner.
Risk of injury or death by electrical shock.
•
Protection objective: Prevent personal injuries or death
•
Electrical failure might cause electrical power to be situated on the metal housing.
Persons who touch the housing might get an electrical shock. This endangers all persons
who might touch the failed product
•
All electrical conducting parts are electrically connected and grounded to protection earth
contact by design of the product. Electrical devices should be tested in regular time
frames depending on local laws and regulations. UVC Air Sanitizers are devices of
protection class 1 and require a protective grounding and may only be connected to
circuits that are protected by a Residual Current Device (RCD)
Risk of injury, product damage or incorrect functionality
•
Protection objective: prevent personal injury, product damage and incorrect functionality.
•
Using non original spare parts may lead to incorrect functionality, broken devices or
injury of humans. These spare parts could be for example screws or UVC tubes This
endangers persons who are near the product and could be caused by falling objects,
electrical shock etc.
•
Avoid incorrect functionality or product damage or injury of persons by only using original
spare parts.
Disposal
•
Protection objective: avoid incorrect disposal and risk for humans and nature.
•
Disposing the product needs to be done correctly following local laws and regulations.
Wrong disposal endangers mankind and nature.
Risk of product damage or injury by wrong cleaning procedure
•
Protection objective: prevent personal injury and product damage
•
No water, air pressure, immersion or anything else should be used to clean the UVC Air
Sanitizer. Incorrect cleaning procedure / treatment causes a risk for personal injury and
damage on the device.
•
The UVC Air sanitizer product shall only be cleaned with a dry soft cloth.
Risk of product damage or injury by non-intended usage
•
Protection objective: avoid personal injury and product damage
•
The product shall not be used for other than its intended purpose.