3.
Insert the cleaning cartridge in the CTS.
The remainder of the cleaning cycle is performed automatically
by the CTS. When the cleaning cycle is complete, the cleaning
cartridge is unloaded and ejected from the CTS. The cleaning
cycle may range from 2 to 3 minutes.
Note:
If there are no more cleaning cycles remaining for the
cleaning cartridge, it will be ejected.
4.
To confirm that a cleaning was done, perform either or both of
the following steps:
Look at the LEDs on the front panel. If the cleaning cycle
was successful, the top and bottom LEDs will be off. If the
cleaning cycle was not performed, the LEDs will continue to
flash.
Issue a REQUEST SENSE (03h) command and check the
setting of the CLND bit. If set to 1, the CLND bit indicates
that a successful cleaning cycle was performed. If the CLND
bit is 0, the cleaning cycle was not performed.
5.
If the cleaning cycle was successful, record the date the cleaning
was performed on the cleaning cartridge label (as shown in
Figure 2-1). Store the cleaning cartridge for future use if it still
has cycles remaining. Or, discard it if no more cleaning cycles
remain.
Note:
If the cleaning cycle was not successful, try another
cleaning cartridge. Make sure you are using an
EXABYTE or EXABYTE-approved 8mm cleaning
cartridge.
2
-
4
510702
2 Cleaning the CTS
Содержание EXB-8205
Страница 1: ...510702 000 0 538 0 838 PP 7DSH ULYHV 0DLQWHQDQFH ...
Страница 2: ...EXB 8205 EXB 8505 8mm Cartridge Tape Subsystems Maintenance ...
Страница 5: ...Notes iv 510702 ...
Страница 9: ...viii 510702 ...
Страница 29: ...Notes 1 16 510702 1 Before You Begin ...
Страница 43: ...Notes 3 10 510702 3 Loading New Microcode from Tape ...
Страница 101: ...Notes I 4 510702 Index ...