Design and function
PC Interfaces
84
099-005231-EW501
10.05.2012
5.11
PC Interfaces
CAUTION
Equipment damage or faults may occur if the PC is connected incorrectly!
Not using the SECINT X10USB interface results in equipment damage or faults in signal
transmission. The PC may be destroyed due to high frequency ignition pulses.
• Interface SECINT X10USB must be connected between the PC and the welding machine!
• The connection must only be made using the cables supplied (do not use any additional
extension cables)!
PC 300 welding parameter software
Create all welding parameters quickly on the PC and easily transfer them to one or more welding
machines (accessories: set consisting of software, interface, connection leads).
5.12
Protecting welding parameters from unauthorised access
To protect against unauthorised or unintentional adjustment of the welding parameters on the machine,
the control input can be locked with the aid of a key switch.
In key switch position 1 all functions and parameters can be set without restriction.
In key switch position 0 the following functions and parameters cannot be changed:
• Job switching function, welding task selection
(block job mode possible with Power-control torch)
• Job
Manager
mode
• Program
Steps
mode
• Program
A
mode
• Job Info mode
• Super pulse function
NOTE
The function of the key switch is implemented with a special parameter. See chapter
"Advanced Settings"
Содержание Taurus 401 Synergic FKG
Страница 6: ...Contents Notes on the use of these operating instructions 6 099 005231 EW501 10 05 2012...
Страница 20: ...Machine description quick overview Rear view 20 099 005231 EW501 10 05 2012 4 2 Rear view Figure 4 2...
Страница 37: ...Design and function MIG MAG welding 099 005231 EW501 10 05 2012 37...
Страница 100: ...Appendix B Overview of EWM branches 100 099 005231 EW501 10 05 2012 12 Appendix B 12 1 Overview of EWM branches...