Design and function
TIG welding
78
099-005231-EW501
10.05.2012
Latched mode
t
t
I
1.
2.
3.
4.
P
A
Figure 5-44
Selection
• Select latched operating mode
.
Step 1
• Press and hold torch trigger
• Shielding gas is expelled (gas pre-flows)
The arc is ignited using liftarc.
• Welding current flows with pre-selected setting.
Step 2
• Release torch trigger (no effect)
Step 3
• Press torch trigger (no effect)
Step 4
• Release torch trigger
• Arc is extinguished.
• Gas post-flow time elapses.