Design and function
TIG welding
099-005231-EW501
10.05.2012
77
Non-latched mode
I
t
t
1.
2.
P
A
Figure 5-42
Selection
• Select non-latched operating mode
.
Step 1
• Press and hold torch trigger.
• Shielding gas is expelled (gas pre-flows).
The arc is ignited using liftarc.
• Welding current flows with pre-selected setting.
Step 2
• Release torch trigger.
• Arc is extinguished.
• Gas post-flow time elapses.
Special, non-latched
t
t
I
1.
2.
P
A
P
END
P
START
Figure 5-43
Selection
• Select non-latched special mode
.
Step 1
• Press and hold torch trigger
• Shielding gas is expelled (gas pre-flows)
The arc is ignited using liftarc.
• Welding gas flows with pre-selected setting in start program “P
START
”.
• After the “tstart” ignition current time elapses, the welding current rises with the set upslope time “tS1”
to the main program “P
A
”.
Step 2
• Release torch trigger.
• The welding current reduces with the downslope time “tSe” to the end program “P
END
”.
• After the end current time “end” elapses, the arc will extinguish.
• Gas post-flow time elapses.