Design and function
Shielding gas supply
099-005231-EW501
10.05.2012
33
5.7.4
Setting the shielding gas quantity
Welding process
Recommended shielding gas quantity
MAG welding
Wire diameter x 11.5 = l/min
MIG brazing
Wire diameter x 11.5 = l/min
MIG welding (aluminium)
Wire diameter x 13.5 = l/min (100 % argon)
TIG
Gas nozzle diameter in mm corresponds to l/min gas throughput
Helium-rich gas mixtures require a higher gas volume!
The table below can be used to correct the gas volume calculated where necessary:
Shielding gas
Factor
75% Ar/25% He
1.14
50% Ar/50% He
1.35
25% Ar/75% He
1.75
100% He
3.16
NOTE
Incorrect shielding gas setting!
If the shielding gas setting is too low or too high, this can introduce air to the weld pool
and may cause pores to form.
• Adjust the shielding gas quantity to suit the welding task!
Содержание Taurus 401 Synergic FKG
Страница 6: ...Contents Notes on the use of these operating instructions 6 099 005231 EW501 10 05 2012...
Страница 20: ...Machine description quick overview Rear view 20 099 005231 EW501 10 05 2012 4 2 Rear view Figure 4 2...
Страница 37: ...Design and function MIG MAG welding 099 005231 EW501 10 05 2012 37...
Страница 100: ...Appendix B Overview of EWM branches 100 099 005231 EW501 10 05 2012 12 Appendix B 12 1 Overview of EWM branches...