Design and function
MIG/MAG welding
099-005231-EW501
10.05.2012
45
5.8.10
MIG/MAG welding data display
To the left and right of the control displays are the "Parameter selection" buttons (
). They are used to
select welding parameters to be displayed.
Each press of the button advances the display to the next parameter (LEDs next to the button indicate the
selection). After the last parameter is reached, the system starts again from the beginning.
HOLD
AMP
VOLT
PROG
Taurus Synergic
Figure 5-14
The display shows:
• Nominal values (before welding)
• Actual values (during welding)
• Hold values (after welding)
Parameter
Nominal values
Actual values
Hold values
Welding current
;
;
;
Material thickness
;
Wire speed
;
;
;
Welding voltage
;
;
;
When the settings are changed (e.g. wire speed), the system switches over immediately to the
setpoint setting.