Functional characteristics
Machine configuration menu
66
099-00T500-EW501
2.9.2022
Display
Setting/selection
Pulsed TIG welding (thermal)
------- Function enabled (ex works)
------- For special applications only
Filler wire welding, operating mode
2
-------- Filler wire operation for automated applications,
wire is fed when current flows
-------- Non-latched operating mode (ex works)
-------- 3rd cycle operating mode
-------- Latched operating mode
TIG antistick
> see 5.2.7 chapter
-------- function active (factory setting).
------- function inactive.
Average value controller (AC)
1
-------- Function enabled (factory setting)
------- Function disabled
activArc voltage measuring
-------- Function enabled (ex works)
------- Function disabled
Fast take-over of control voltage (automation)
3
-------- Function enabled
------- Function disabled (ex works)
Welding procedure DC+ (TIG)
1
Protection against an accidental selection of polarity DC+ and the associated destruction
of the tungsten electrode (factory setting).
-------- Polarity switching to DC+ is possible.
------- Polarity switching is disabled (factory setting).
Gas monitoring
Depending on where the gas sensor is situated, the use of a pilot static tube and the
welding process monitoring phase.
------- Function disabled (ex works).
------- Monitoring during the welding process. Gas sensor between gas valve and
welding torch (with pilot static tube).
------- Monitoring prior to the welding process. Gas sensor between gas valve and
welding torch (without pilot static tube).
------- Permanent monitoring Gas sensor between gas cylinder and gas valve (with
pilot static tube).
Arc detection for welding helmets (TIG)
Modulated waviness for better arc detection
------- Function disabled
------- Medium intensity
------- High intensity
1
for AC welding machines only.
2
For machines with filler wire (AW) only.
3
only for machines with an interface for automated welding or appropriate automation components.