Rectifying faults
Resetting welding parameters to the factory settings
099-00T500-EW501
2.9.2022
77
Error 57: Slave tacho error
Category B
Fault in the wire feeder (slave drive).
Check the connections (connectors, lines).
Permanent overload of the wire drive (slave drive).
Do not lay the liner in tight radii.
Check the liner for smooth movement.
Error 58: Short circuit
Category B
Short circuit in the welding circuit.
Eliminate the short circuit in the welding circuit.
Place the welding torch on an insulated surface.
Error 59: Incompatible machine
A machine connected to the system is not compatible.
Disconnect the incompatible machine from the system.
Error 60: Incompatible software
The software of a machine is not compatible.
Disconnect the incompatible machine from the system
Request service.
Error 61: Welding monitoring
The actual value of a welding parameter is outside the specified tolerance range.
Maintain the tolerance ranges.
Adjust the welding parameters.
Error 62: System component
The system component was not found.
Request service.
Error 63: Mains voltage error
Operating and mains voltage are incompatible.
Check or adjust the operating and mains voltage.
[1]
See technical data for values and other switching thresholds.
7.3 Resetting welding parameters to the factory settings
All customised welding parameters that are stored will be replaced by the factory settings.
To reset the welding parameters or machine settings to the factory settings, select parameter
in the
service menu
> see 5.11 chapter
.
7.4 Software version of the machine control
The query of the software versions only serves to inform the authorised service staff. It is available in the
machine configuration menu
> see 5.11 chapter
.