Functional characteristics
Machine configuration menu
62
099-00T500-EW501
2.9.2022
Display
Setting/selection
Exit the menu
Exit
Switching the machine off and on
Required for applying various configuration parameters
Power source menu
Switch ignition mode
-------- HF ignition
------- Liftarc
HF intensity
------- Standard: Maximum value for the high-voltage ignition pulse Up
------- Reduced: Reduced value for the high-voltage ignition pulse Up
Re-ignition after arc interruption
> see 5.2.4.3 chapter
------- JOB-dependent time (ex works 5 s).
------- Function disabled or numerical value 0.1–5.0 s.
Reconditioning pulse (tungsten ball stability)
1
Cleaning effect of the tungsten ball at the end of welding.
-------- Function enabled (ex works)
------- Function disabled
TIG HF start (soft/hard) switching
-------- soft ignition (factory setting).
------- hard ignition.
Ignition pulse dynamics
-------- Function enabled (factory setting)
------- Function disabled
Minimum current limit (TIG)
> see 5.1.2 chapter
Depending on the set tungsten electrode diameter
------- Function disabled
-------- Function enabled (ex works)
Time-based power-saving mode
> see 5.7 chapter
Time to activation of the power-saving mode in case of inactivity.
Setting
= disabled or numerical value 5-60 min..
Cable resistance alignment
> see 5.2.13 chapter
Access control – access code
Setting: 000 to 999 (000 ex works)
Access control
> see 5.8 chapter
-------- Function enabled
------- Function disabled (ex works)
Operating mode menu
Program mode
------- Function disabled (factory setting)
-------- Function enabled
Program lock (P0)
The program P0 is locked when locking with the key switch. It is only possible to switch
between programs P1 to P15.
------- Function disabled (factory setting)
-------- Function enabled
Operating principle
------
synergic parameter setting (factory setting)
------
conventional parameter setting