Functional characteristics
Welding programs
099-00T500-EW501
2.9.2022
47
TIG function torch, Retox XQ
Figure 5-34
Function
Operation
Mode
Welding current On / Off
BRT 1
1
Secondary current (in latched operation)
Secondary current (in latched operation)
BRT 2
Increase welding current (up/down speed)
UP
Decrease welding current (up/down speed)
DOWN
Welding current On / Off
BRT 1
4
Secondary current (in latched operation)
Secondary current (in latched operation)
BRT 2
Increase welding current in steps (current jump)
UP
Decrease welding current in steps (current jump)
DOWN
Switching between current jump and JOB
BRT 2
Increase JOB number
UP
Decrease JOB number
DOWN
Gas test
BRT 2
3 s
Welding current On / Off
BRT 1
5
Secondary current (in latched operation)
Secondary current (in latched operation)
BRT 2
Increase program number
UP
Decrease program number
DOWN
Switching between program and JOB
BRT 2
Increase JOB number
UP
Decrease JOB number
DOWN
Gas test
BRT 2