Functional characteristics
Power-saving mode (Standby)
60
099-00T500-EW501
2.9.2022
5.6.2 Reset welding task (JOB) to the factory setting
This function resets the JOB data of a welding task (JOB) to be selected to the factory settings.
4s
2s
Figure 5-53
5.7 Power-saving mode (Standby)
You can activate the power-saving mode by either pressing the push-button
> see 4 chapter
for a prolon-
ged time or by setting a parameter in the machine configuration menu (time-controlled power-saving
mode
)
> see 5.11 chapter
.
When power-saving mode is activated, the machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. turning a rotary knob) deactivates power-saving mode and the ma-
chine is ready for welding again.
5.8 Access control
The machine control can be locked to secure it against unauthorised or unintentional adjustment. The
access block has the following effect:
• The parameters and their settings in the machine configuration menu, Expert menu and operation se-
quence can only be viewed but not changed.
• Welding procedure and welding current polarity cannot be changed.
The parameters for setting the access block are configured in the machine configuration
menu
> see 5.11 chapter
.
Enabling access block
• Assign the access code for the access block: Select parameter
and select a number code (0–
999).
• Enable access block: Set parameter
to access block enabled
.
The access block activation is indicated by the "Access block active" signal light
> see 4 chapter
.
Disabling access block
• Enter the access code for the access block: Select parameter
and enter the previously selected
number code (0–999).
• Disable access block: Set parameter
to access block disabled
. The only way to disable the
access block is to enter the selected number code.