Operating the machine control
Welding task administration (Menu)
099-00L105-EW501
07.06.2019
51
5.6.8 Welding monitoring
Figure 5-28
Item Symbol Description
0
1
Current tolerance
2
WF tolerance
3
Voltage tolerance
4
Advanced settings
Display and setting of advanced system parameters
5
WPQR WPQR welding data assistant
Menu item / parameter
Value
Comment
Automatic
No
Yes
The welding monitoring window opens auto-
matically from the main screen after a welding
start. A rotary knob actuation automatically
switches back to the main window.
Errors and warnings
Off
Warnings
Exceeding a tolerance limit for the duration of
the tolerance response time triggers warning
12.
Error
Exceeding a tolerance limit for the duration of
the tolerance response time triggers error 61.
Please note: Error leads to immediate stop of
the ongoing welding!
Voltage tolerance
0-100 %
Current tolerance
0-100 %
Tolerance response time
0.00-20.0 s
For voltage and current tolerance
Wire feeder tolerance
0-100 %
Maximum permissible motor current
0.0-5.0 A
Tolerance response time
0.00-20.0 s
For WF tolerance and motor current
5.6.9 JOB display setting
Menu item/parameter
Value
Comment
Text for material:
Standard
Alternative
Text for gas:
Standard
Alternative
Absolute value set point:
Yes
Ignition current, secondary current and end
current are set and displayed as absolute va-
lues
No
Ignition current, secondary current and end
current are defined and displayed as a percen-
tage of program A (ex works)