Operating the machine control
Welding task administration (Menu)
099-00L105-EW501
07.06.2019
45
5.6.5.2 MIG/MAG welding
In every JOB, separate settings can be made for the ignition program, reduced main program and end
program as to whether or not to alternate with the pulse process.
These properties are stored on the welding machine with the JOB. This means that in the factory settings,
the pulse process is active during the end program in all forceArc JOBs.
Figure 5-24
P
START
, P
B
and P
END
are set as relative programs ex factory. They relate to percentages of the wire
feed value of the main program P
A
. These programs can also be configured using absolute values,
if desired (see Absolute value set point).
> see 5.6.9 chapter
.
Menu item/parameter
Program
Comment
Gas pre-flow time
Gas nominal value
GFE option/variant (electronic gas volume con-
trol) required
WF relative
P
START
Wire feed speed, relative
Duration
Duration (start program)
U correction
Arc length correction
Slope time
Slope duration from P
START
to P
A
WF (/min.)
P
A
Wire feed speed, absolute
U correction
Arc length correction
Duration
Duration (spot time and superPuls time)
Slope time
Slope duration from P
A
to P
B
WF relative
P
B
Wire feed speed, relative
Duration
Duration (reduced main program)
U correction
Arc length correction, relative
Slope time
Slope duration from P
B
to P
A
Slope time
Slope duration from P
B
to P
END
WF relative
P
END
Wire feed speed, relative
Duration
Duration (end program)
U correction
Arc length correction, relative
Wire burn-back
Gas post-flow time