89
HPS-III-Heißkanalsystem_Elektro-System_BA_V-2-0_EN
Picture 59: Cable assignment of HPS III manifolds (shown: one control zone)
z343-03
Picture 60: Cable assignment of heater bands for sprue bushs (one control zone)
z343-04
Generally the cable pairs for heaters are brown and blue (manifold heaters) and orange and grey (nozzle heaters)
respectively. A sufficient protective earthing of the hot runner system must be ensured.
Furthermore, thermocouples type J (Fe-CuNi) are used. The hot runner controller used must be designed to work with that
type. The wiring follows the wiring plan of the hot runner system. Generally the cable pairs are black (+) and white (-).
230V
Thermo
L (brown)
N (blue)
+ (black)
- (white)
230V
Thermo
Side view of manifold
Top view of manifold
Top view of manifold
230V
Thermo
L (black)
N (blue)
+ (black)
- (white)
230V
Thermo
Electrical connection of hot runner systems
Содержание HPS III
Страница 2: ......
Страница 116: ...116 HPS III Hei kanalsystem_Instandhaltung F hlerwechsel S SXE_BA_V 2 0_EN...
Страница 122: ...122 HPS III Hei kanalsystem_Instandhaltung F hlerwechsel S SXE_BA_V 2 0_EN Maintenance...
Страница 126: ...126 HPS III Hei kanalsystem_Instandhaltung F hlerwechsel S SXE_BA_V 2 0_EN Maintenance...