HPS-III-Nadelverschluss-Heißkanalsystem_Montage_BA_V-2-0_EN
Installation of HPS III valve gate hot runner systems
Pos. 1 Manifold
Pos. 5 Sprue bush
Pos. 6 Locating ring
Pos. 8 Drive unit integrated in clamping plate (version 2)
Pos. 17 Valve pin
Pos. 19 Synchronous plate
Pos. 20 Screw for valve pin holder
Pos. 21 Valve pin holder
Pos. 22 Overload safety device for valve pin
Pos. 23 Shoulder screw
Pos. 24 Guiding system (version 1)
Pos. 25 Guiding system (version 2)
(for restriceted installation space)
Pos. 50 Insulating plate
Pos. 51 Clamping plate
Pos. 53 Nozzle retainer frame plate
Pos. 54 Intermediate plate
Pos. 56 Contour plate
Installation of synchronous plate valve gate systems for HPS III-S nozzles
for standard and front installation
Read operating manual
In the installation process described in the following hazards for the
personal health are listed explicitly.
Furthermore, during installation the warning, safety and installation
notes for installation of EWIKON hot runner systems and compo-
nents as specified in chapter „5.2 General safety instructions“ must
be followed!
NOTE!
Dimensional check
Before installation the installation dimensions as listed in chapter
„5.4 Checks before installation“ must be checked and compared with
the values provided with the installation drawing.
Use approved standard parts only
Only standard parts which are approved for use in EWIKON hot
runner systems must be used. See chapter „5.3 Technical Requi-
rements“.
Screw connection for manifold
The screw connection for the manifold (pos. 13) is only required
when nozzles for standard installation are used.
When nozzles for
front installation are installed the manifold must not be screw
connected.
NOTE!