Installation of HPS III valve gate hot runner systems
Picture 34: Installation of an integrated drive unit (Version 2)
z342-09
1. Apply a thin coat of high performance grease
(see chapter „5.3.1 Tools and operating materials“)
to all surfaces marked with (A).
2. Apply high temperature installation paste
(see chapter „5.3.1 Tools and operating materials“)
to all surfaces marked with (B).
3. Insert and screw-in the screw-in housing cover (pos. 8.1)
into the clamping plate (pos. 51) from below by using
the installation wrench (pos. a). Tighten with matching
torque. See chapter „9. Tightening torques“.
4. Slide the screw-in housing cover (pos. 8.1) on the piston
(pos. 8.2) from above. Insert both components carefully
and without tilting so that the piston slides into the alrea-
dy fitted screw-in housing cover (pos. 8.1). Be careful
not to damage the sealings.
5. Screw the screw-in housing cover (pos. 8.1) into the
clamping plate (pos. 51) by using the installation wrench
(pos. a) and tighten with matching torque. See chapter
„9. Tightening torques“.
5.5.6 Drive unit integrated in clamping plate (version 2) -
Installation in the clamping plate
WARNING!
Sharp edges and heavy components
•
Cut injuries to body and extremities, mainly to the hands.
•
Crushing of fingers or hand.
Pressurized systems
During installation all hydraulic or pneumatic supply lines must be de-
pressurised.
•
Injuries caused by flying parts or "whipping" hoses.
•
Injuries to eyes caused by escaping pressurised liquids.