48
WT.025.200.000.DE.IM 0517
Operation
S10k
5.
3
Gas control unit will not
run up to full capacity
Insufficient injector vacuum
see 1.
Injector does not meet re-
quirements
Change injector parts
Gas filter in vacuum de-
mand valve clogged
Replace the filter
4
Flowmeter float moves
erratically
Deposits on flowmeter parts
Clean flowmeter
5
Odour of chlorine in
chlorinator room or vi-
cinity
Pressure relief valve blows
Clean resp. replace vacuum de-
mand valve. Replace the filling of
the activated carbon filter.
6
Water in flowmeter
Defective check valve in in-
jector
Dry the system, check injector
7
Gas feed rate cannot
be adjusted properly
V-notch stem worn
Replace V-notch stem
V-notch orifice worn
Replace orifice
Vacuum demand valve de-
fective
Replace vacuum demand valve
No.
Symptoms
Probable cause
Remedy
Содержание WALLACE & TIERNAN S10k
Страница 1: ...WALLACE TIERNAN GAS FEEDER S10k INSTRUCTION MANUAL ...
Страница 2: ...2 WT 025 200 000 DE IM 0517 S10k Please note Original manual ...
Страница 6: ...6 WT 025 200 000 DE IM 0517 Contents S10k ...
Страница 22: ...22 WT 025 200 000 DE IM 0517 Description S10k 3 ...
Страница 88: ...88 WT 025 200 000 DE IM 0517 Drawings S10k 7 7 4 Spare parts for the injectors 7 4 1 Injector W3T171367 1 ...
Страница 90: ...90 WT 025 200 000 DE IM 0517 Drawings S10k 7 7 4 2 Anti syphon injector W3T171368 1 ...
Страница 93: ...S10k Drawings 7 93 ...
Страница 94: ...94 WT 025 200 000 DE IM 0517 Drawings S10k 7 7 4 3 Injector W3T171369 3 4 ...
Страница 96: ...96 WT 025 200 000 DE IM 0517 Drawings S10k 7 7 4 4 Antisyphon Injektor W3T171370 3 4 ...
Страница 99: ...S10k Manufacturer declaration 8 99 8 Manufacturer declaration ...
Страница 100: ...100 WT 025 200 000 DE IM 0517 Manufacturer declaration S10k 8 ...