S10k
Installation
4.
25
If the flowmeter assembly is bolted to an uneven wall, shims must
be added to prevent the flowmeter assembly from twisting when
the bolts are tightened. The axis of the flowmeter assembly must
be vertical when mounted. Use a spirit level to check this.
4.3.1
Mounting the flowmeter
Note
For protection in shipment, the flowmeter and associated parts
were removed after the flowmeter assembly was factory tested.
These parts are separately packaged and should be assembled
and installed as indicated.
Install the flowmeter as follows:-
1
Insert a coin or similar into the slot in the bottom of the flowme-
ter jackscrew. Unscrew it counter-clockwise from the bottom.
Remove it. (Refer to 7.3.3 or 7.3.4)
2
Insert one gasket in the top of the flowmeter frame.
3
Insert lower stop and float and top stop into the flowmeter
tube.
4
Carefully raise the flowmeter tube with its parts into the frame.
5
Insert the O-ring on top of the flowmeter jackscrew.
6
Engage the flowmeter jackscrew in its threaded opening and
tighten by hand.
7
Tighten the flowmeter jackscrew gently until a firm seal is
achieved.
Caution!
Do not overtighten as this may break the flowmeter tube.
4.4
Installing the vacuum demand valve
Caution!
When the vacuum demand valve is used with carbon dioxide,
pressure valves, reducing valves, pressure relief valves and all re-
lated pipework and fittings between the gas supply and the vacu-
um demand valve, must be obtained from the gas supplier; they
must be installed in accordance with his recommendations.
Not all drawings and text in this book are applicable to carbon dio-
xide systems.
Gas supply pressure must be reduced to between 1.4 and 13.5
Содержание WALLACE & TIERNAN S10k
Страница 1: ...WALLACE TIERNAN GAS FEEDER S10k INSTRUCTION MANUAL ...
Страница 2: ...2 WT 025 200 000 DE IM 0517 S10k Please note Original manual ...
Страница 6: ...6 WT 025 200 000 DE IM 0517 Contents S10k ...
Страница 22: ...22 WT 025 200 000 DE IM 0517 Description S10k 3 ...
Страница 88: ...88 WT 025 200 000 DE IM 0517 Drawings S10k 7 7 4 Spare parts for the injectors 7 4 1 Injector W3T171367 1 ...
Страница 90: ...90 WT 025 200 000 DE IM 0517 Drawings S10k 7 7 4 2 Anti syphon injector W3T171368 1 ...
Страница 93: ...S10k Drawings 7 93 ...
Страница 94: ...94 WT 025 200 000 DE IM 0517 Drawings S10k 7 7 4 3 Injector W3T171369 3 4 ...
Страница 96: ...96 WT 025 200 000 DE IM 0517 Drawings S10k 7 7 4 4 Antisyphon Injektor W3T171370 3 4 ...
Страница 99: ...S10k Manufacturer declaration 8 99 8 Manufacturer declaration ...
Страница 100: ...100 WT 025 200 000 DE IM 0517 Manufacturer declaration S10k 8 ...