12
WT.050.810.040.DE.IM.0519
Description
DEPOLOX
®
5 E flow cell
3.
DEPOLOX
®
5 E flow cell is available in both a non-pressurized and a
pressurized version. The two versions differ in the number of sensors that
can be installed and in the design of the sample water outlet. The pres
-
surized version can be retrofitted with the total chlorine membrane sen
-
sor TC3 CAN. Please note that the standard cell body cover must be
replaced by an optional cell body cover, part no. W3T417351. The non-
pressurized version is characterized by a free sample water outlet. With
the pressurized version, the sample water is returned into the system’s
circuit.
The for sensors required for the measurement tasks (optional) and the
LED glow stick are inserted or screwed into the mounting hole in the cell
body cover.
The maintenance-free flow control valve is the main hydraulic part of
DEPOLOX
®
5 E flow cell. It has the task of keeping the sample water flow
constant, irrespective of fluctuations in operating pressures.
The multi-sensor monitors the correct flow and records the temperature
of the sample water. The metallic sensor housing guarantees good sam
-
ple water earthing. The continuous hydromechanical cleaning of the
electrode of the three-electrode measuring cell effectively prevents natu
-
ral contamination of the electrode surfaces and ensures long-term stable
chlorine measurement.
DFMe electronics module converts the analog sensor signals for digital
transmission to 700 P electronics module or 700 M electronics module. If
a membrane sensor for total chlorine TC3 CAN (optional) is used, this is
connected directly to DFMe electronics module or routed through the
CAN connection on conductivity module SiDiSens (optional) to DFMe
electronics module. The conductivity sensor (optional) is connected to
DFMe electronics module through conductivity module SiDiSens.
3.2
Versions
The DEPOLOX
®
5 E flow cell (module type D01) can be comined with
700 P electronics module (module type E01) or 700 M electronics module
(module type E01). The following versions are available:
• Pool Management System DEPOLOX
®
5 E 700 P
• Measuring and control unit DEPOLOX
®
5 E 700 M
Содержание WALLACE & TIERNAN DEPOLOX 5 E 700 P Series
Страница 1: ...WALLACE TIERNAN DEPOLOX 5 E FLOW CELL INSTRUCTION MANUAL...
Страница 2: ...2 WT 050 810 040 DE IM 0519 DEPOLOX 5 E flow cell Please note Original instruction manual Simone...
Страница 56: ...56 WT 050 810 040 DE IM 0519 Maintenance DEPOLOX 5 E flow cell 5...
Страница 72: ...72 WT 050 810 040 DE IM 0519 Declarations and certificates DEPOLOX 5 E flow cell 7...
Страница 76: ...76 WT 050 810 040 DE IM 0519 Declarations and certificates DEPOLOX 5 E flow cell 7...
Страница 80: ...80 WT 050 810 040 DE IM 0519 Index DEPOLOX 5 E flow cell 8...