W3T331759 / WT.050.585.003.UE.IM.1014
34
MICRO/2000® AND DEOX/2000® MODULE
The exact depiction of the individual parameters on the graphic display
is described in section 4.3, Menu Structure.
4.1.1 Operator controls
Softkey
•
Activate the function shown on the graphic
display with the keys.
Up
•
Move up one level.
•
Display the previous option.
•
Increase the value.
Down
•
Move down one level.
•
Display the next option.
•
Decrease the value.
Left/right
•
Change the column in the menu.
•
Change the position in the displayed value (cursor menu).
•
Move forwards or backwards by six hours in the trend graph.
Escape
•
Cancel the entry without saving the new value.
•
Move up one menu level.
Enter/Acknowledge
•
Acknowledge alarm message.
•
Set the running delays to zero.
•
Delete adaption error.
•
Acknowledge max. dosing time to reactivate dosing.
4.2
Notes On Operation
During operation observe the following points:
•
Check your entry and modifications before exiting the menu.
•
Only press the keys with your fingers, never with hard or pointed
objects such as pencils, etc. This could damage the sealed keypad.
4.2.1 Operation
You have the following options starting from the basic display (the basic
display is opened by pressing the "ESC" key in the menu four times):
ESC
3
Содержание WALLACE & TIERNAN DEOX/2000
Страница 4: ......
Страница 10: ...W3T331759 WT 050 585 003 UE IM 1014 6 MICRO 2000 AND DEOX 2000 MODULE...
Страница 30: ...W3T331759 WT 050 585 003 UE IM 1014 26 MICRO 2000 AND DEOX 2000 MODULE...
Страница 46: ...W3T331759 WT 050 585 003 UE IM 1014 42 MICRO 2000 AND DEOX 2000 MODULE...
Страница 74: ...W3T331759 WT 050 585 003 UE IM 1014 70 MICRO 2000 AND DEOX 2000 MODULE...