4. Safety Instructions 

Ensure that all safety instructions and recommendations are always adhered to. Failure to comply with these 
recommendations could void the warranty and cause injury or death. 

 

Installation, repair, or relocations must only be done by a 
fully qualified technician. 

 

The Evo315-C must be installed to conform to all relevant 
Australian Standards and Industry Codes including but 
not limited to: Electrical & Electrical Safety, Plumbing & 
Hot Water Storage, Heat Pump Installation & Operation 

 

A circuit breaker must be installed for the unit. 

 

Ensure the unit has a good power connection and 
earthing to avoid the risk of electrical shocks. 

 

Ensure that there are no leaks on both the plumbing and 
drainage fittings. 

 

The unit must not be installed near flammable gas or have 
flammable aerosols sprayed in the vicinity. 

 

The base that the unit is installed on must be level and 
stable. 

 

If the supply cord is damaged, it must be replaced by a 
qualified service agent. 

 

This appliance must be installed in accordance with 
national wiring regulations. 

 

Installation must also comply with any local, state or 
federal codes at the installation site. Failure to comply can 
void your warranty, damage your unit or possible cause 
injury or death. Plumbing must comply with 
AS/NZS3500.4 

 

Before obtaining access to terminals all supply circuits 
must be disconnected. 

 

A P&T valve 

MUST 

be installed in the tank. When the 

tank pressure reaches 0.85MPa or when the tank 
temperature reaches 99°C, the P&T valve will open 
automatically so as to reduce the pressure or temperature 
decrease. 

 

In the event of the unit malfunctioning, shut off the 
power supply and contact your supplier or EvoHeat. 

 

In order to use the unit correctly, run the unit at 
environment temperature -5°C - 43°C 

 

The unit contains sophisticated electronic devices, do 
not use unsafe water sources such as lake or 
groundwater. 

 

The unit produces hot water and will also have hot 
fittings, therefore should not be touched to avoid injury. 

 

Do not drill any fixings or attachments into the outer 
casing of the tank. Drilling into the outer casing of the 
tank may damage the heating coil and 

WILL VOID 

WARRANTY.

 

 

If the unit stops and you restart the unit or turn it on 
manually, the unit will not start to run again for 
approximately 3 minutes. This is a protection feature to 
safeguard the compressor. 

 

The handle of the P&T safety valve should be tested 
once every six months to remove the calcium 
carbonate deposits and guarantee there is no blockage 
in the device. 

 

Once installation is complete, check that all 
connections are secure before the power is turned on. 

 

The installer is to explain to the end user how to 
operate and maintain the unit in accordance with this 
instruction manual. 

 

Evo Industries Australia Pty Ltd will not be held 
responsible for any damages or injuries caused by the 
incorrect installation of this hot water system. 

 

A maintenance programme must be carried out as 
recommended in this manual to ensure ongoing 
reliability. 

To reduce the risk of excessive pressures and temperatures in this water heater, install temperature and pressure protective 
equipment required by local codes and no less than a combination temperature and pressure relief valve certified by a nationally 
recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the 
requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSIZ21.22. This valve must be 
marked with a maximum set pressure not to exceed the marked maximum working pressure of the water heater. Install the valve 
into an opening provided and marked for this purpose in the water heater, and orient it or provide tubing so that any discharge from 
the valve exits only within 6 inches above, or at any distance below, the structural floor, and does not contact any live electrical 
part. The discharge opening must not be blocked or reduced in size under any circumstances. 

 
Hydrogen gas is produced in a hot water system served by this heater that has not been used for a long period of time (2 weeks or 
more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot 
water faucet be opened for several minutes at the kitchen sink before using any electrical appliance. 

 
The appliance is fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full 
disconnection under overvoltage category lll conditions, and these means must be incorporated in the fixed wiring in accordance 
with the wiring rules. 

 

 

 

 

Содержание Evo315-C

Страница 1: ......

Страница 2: ...ller 7 6 2 Operating Functions 8 6 2 1 Startup Shutdown 8 6 2 2 Switching Modes 8 6 2 3 Locking the Controller 8 6 2 4 Setting Checking the Target Temperature 9 6 2 5 Hydroboost Setting 9 6 2 6 Force...

Страница 3: ...dvanced energy efficiency technologies and built in smart features to ensure you re provided with clean safe and economical hot water all year round Conforms to AS 3498 2009 Australia and New Zealand...

Страница 4: ...year d Press at any stage to cancel 3 Press until is displayed This will activate Eco Heating Heat Pump only mode and will provide the most efficient heating 4 During periods of unusually high hot wa...

Страница 5: ...you restart the unit or turn it on manually the unit will not start to run again for approximately 3 minutes This is a protection feature to safeguard the compressor The handle of the P T safety valv...

Страница 6: ...eat resistant and durable Piping for the P T Valve The spec of the valve connecting thread is BSP3 4 internal thread After installation confirm that the drainpipe outlet is exposed in the air When the...

Страница 7: ...nces to allow airflow to circulate through the unit it is advised to keep a minimum gap between walls fences etc of 1000mm on the air inlet outlet sides 300mm rear clearance 600mm overhead clearance W...

Страница 8: ...water temperature and target temperature The electric heater always will be off INTELLIGENT MODE The unit will automatically judge the operation mode according to the ambient temperature HIGH REQUIRE...

Страница 9: ...for 0 5 seconds in the running screen of the controller to turn the unit off The main display will now show OFF The unit will dim the screen and display the standby screen when the controller has not...

Страница 10: ...5 Hydroboost Setting Also known as the Electric heater the Hydroboost setting allows higher levels of hot water to be produced When there are high hot water usage requirements such as guests staying t...

Страница 11: ...ameter value as shown in the below table and press the key to open that value Change the value using the up down arrow keys and press the key to save changes Press to exit the menu Description Paramet...

Страница 12: ...t up time A and end time B Press to save the setting and exit back to the main interface Press and hold for 2 seconds the timer display will flash When the timer display flashes choose the start up ti...

Страница 13: ...sh when it is selected use the arrow keys to select your desired start day then press to save all changes and exit back to the main interface Note Format is mm dd Example The unit will start up on Sep...

Страница 14: ...rs E01 EEV adjustment mode 0 1 1 0 Manual 1 Auto E02 EEV target overheat temp 20 20 5 E03 EEV initial steps 0 500 240 E04 EEV minimum steps 0 500 80 E05 Defrosting EEV steps 0 500 480 System parameter...

Страница 15: ...sor shutdown ambient temp 1 30 90 65 R20 The compressor shutdown ambient temp 2 30 90 55 Timing parameters L01 Whether enable the vacation mode 0 1 0 0 Disable 1 Enable L02 The vacation mode Year 0 99...

Страница 16: ...p setting needs to be reduced if it is too high 4 Check the high pressure switch If the switch is open when the connection is closed replace it Low pressure protection E02 1 Check if the system is lea...

Страница 17: ...BRN BLU Y G 3G2 5mm L N L N N N N N N 1 3 2 4 5 6 7 8 01 N 4 WHT N 4V 1 2 3 4 MTS RESET 1 3 4 2 OUT1 OUT2 OUT3 OUT4 OUT5 AC N 3 4 3 4 CN5 OUT6 CN6 CN1 CN2 12V NET GND 485 A 485 B DI01 DI03 GND DI04 GN...

Страница 18: ...80900421 KP cover 640 22 ABS Black Gloss 9005 Plastic Absorption 14 80708081 KP Top Cover Galvanized sheet 0 8 gray white matte 9006 15 80704839 Fan top cover Galvanized sheet 1 0 Black finish 9005 16...

Страница 19: ...th the water heater 8 4 Using the Overheating Protector The overheating protector is used to turn the power off in an emergency or with power supply issues preventing the water from being heated too h...

Страница 20: ...clean of the unit with a damp cloth MAJOR FIVE YEAR SERVICE It is recommended a major five 5 year service be conducted on the Evo315 C Warning Servicing of a water heater must only be carried out by...

Страница 21: ...ed within the i Costs associated with delivery handling freighting or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 o...

Отзывы: