8.3 Use of the P&T Valve 

 

The P&T valve is used to prevent the temperature or pressure becoming too high inside the tank. When 
the temperature or pressure reaches the set value, the valve will open automatically to force the pressure 
or temperature to decrease 

The handle of the safety valve should be tested once every six months to remove the calcium carbonate deposits and 
guarantee there is no blockage in the device. Take care to avoid burns as the temperature of the discharging water is 
very high.  

Vent pipes should be thermally insulated to prevent safety risks caused by freezing pipes in winter. 

P&T valve: Model: PTR-20, action temperature: 

99˚C, action pressure:0.85MPa  

 

WARNING:

 Failing to operate the relief valve easing gear at least once every six months may result in 

the water heater exploding. Continuous leakage of water from the valve may indicate a problem with the 

water heater. 

 

8.4 Using the Overheating Protector 

The overheating protector is used to turn the power off in an emergency 
or with power supply issues, preventing the water from being heated too 
high. 
 
A thermal cut-out could indicate a possibly dangerous situation. Do not 
reset the thermal cutout until the unit has been serviced by a qualified 
technician. Contact EvoHeat for a service if this occurs before 
attempting to reset. 
 
To return the unit to its normal operation status by resetting manually: 
 

a)  To access the overheat protector, remove the front dark grey 

controller panel. 

b)  Remove the 3 screws on the front panel and push the front 

cover upwards. 

c) 

Remove the remaining screws which cover the overheat 
protector panel.

 

 

Remove the screws and open the cover 

 

 

Press the red button to reset

 

 

8.5 Draining the Water Tank 

1.  Close the cold-water inlet valve into the Evo315-C. 

2.  Open a hot water tap inside the premises. 

3.  Undo the drain plug on the base of the unit to drain 

the water from the system. 
 

8.6 Earthing Methodology 

 

 

 

The water from the hot water tap and the drain plug 

will be hot. Be careful of burns and scalds. Wear 

protective clothing. 

Содержание Evo315-C

Страница 1: ......

Страница 2: ...ller 7 6 2 Operating Functions 8 6 2 1 Startup Shutdown 8 6 2 2 Switching Modes 8 6 2 3 Locking the Controller 8 6 2 4 Setting Checking the Target Temperature 9 6 2 5 Hydroboost Setting 9 6 2 6 Force...

Страница 3: ...dvanced energy efficiency technologies and built in smart features to ensure you re provided with clean safe and economical hot water all year round Conforms to AS 3498 2009 Australia and New Zealand...

Страница 4: ...year d Press at any stage to cancel 3 Press until is displayed This will activate Eco Heating Heat Pump only mode and will provide the most efficient heating 4 During periods of unusually high hot wa...

Страница 5: ...you restart the unit or turn it on manually the unit will not start to run again for approximately 3 minutes This is a protection feature to safeguard the compressor The handle of the P T safety valv...

Страница 6: ...eat resistant and durable Piping for the P T Valve The spec of the valve connecting thread is BSP3 4 internal thread After installation confirm that the drainpipe outlet is exposed in the air When the...

Страница 7: ...nces to allow airflow to circulate through the unit it is advised to keep a minimum gap between walls fences etc of 1000mm on the air inlet outlet sides 300mm rear clearance 600mm overhead clearance W...

Страница 8: ...water temperature and target temperature The electric heater always will be off INTELLIGENT MODE The unit will automatically judge the operation mode according to the ambient temperature HIGH REQUIRE...

Страница 9: ...for 0 5 seconds in the running screen of the controller to turn the unit off The main display will now show OFF The unit will dim the screen and display the standby screen when the controller has not...

Страница 10: ...5 Hydroboost Setting Also known as the Electric heater the Hydroboost setting allows higher levels of hot water to be produced When there are high hot water usage requirements such as guests staying t...

Страница 11: ...ameter value as shown in the below table and press the key to open that value Change the value using the up down arrow keys and press the key to save changes Press to exit the menu Description Paramet...

Страница 12: ...t up time A and end time B Press to save the setting and exit back to the main interface Press and hold for 2 seconds the timer display will flash When the timer display flashes choose the start up ti...

Страница 13: ...sh when it is selected use the arrow keys to select your desired start day then press to save all changes and exit back to the main interface Note Format is mm dd Example The unit will start up on Sep...

Страница 14: ...rs E01 EEV adjustment mode 0 1 1 0 Manual 1 Auto E02 EEV target overheat temp 20 20 5 E03 EEV initial steps 0 500 240 E04 EEV minimum steps 0 500 80 E05 Defrosting EEV steps 0 500 480 System parameter...

Страница 15: ...sor shutdown ambient temp 1 30 90 65 R20 The compressor shutdown ambient temp 2 30 90 55 Timing parameters L01 Whether enable the vacation mode 0 1 0 0 Disable 1 Enable L02 The vacation mode Year 0 99...

Страница 16: ...p setting needs to be reduced if it is too high 4 Check the high pressure switch If the switch is open when the connection is closed replace it Low pressure protection E02 1 Check if the system is lea...

Страница 17: ...BRN BLU Y G 3G2 5mm L N L N N N N N N 1 3 2 4 5 6 7 8 01 N 4 WHT N 4V 1 2 3 4 MTS RESET 1 3 4 2 OUT1 OUT2 OUT3 OUT4 OUT5 AC N 3 4 3 4 CN5 OUT6 CN6 CN1 CN2 12V NET GND 485 A 485 B DI01 DI03 GND DI04 GN...

Страница 18: ...80900421 KP cover 640 22 ABS Black Gloss 9005 Plastic Absorption 14 80708081 KP Top Cover Galvanized sheet 0 8 gray white matte 9006 15 80704839 Fan top cover Galvanized sheet 1 0 Black finish 9005 16...

Страница 19: ...th the water heater 8 4 Using the Overheating Protector The overheating protector is used to turn the power off in an emergency or with power supply issues preventing the water from being heated too h...

Страница 20: ...clean of the unit with a damp cloth MAJOR FIVE YEAR SERVICE It is recommended a major five 5 year service be conducted on the Evo315 C Warning Servicing of a water heater must only be carried out by...

Страница 21: ...ed within the i Costs associated with delivery handling freighting or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 o...

Отзывы: