6. Operation 

6.1 The Controller 

 

 

ON/OFF 

Turn the unit on or off. 

 

UP 

Select options to increase values 

 

DOWN 

Select options to decrease values 

 

CLOCK 

Set the clock or the timer. 

 

HYDROBOOST 

Turn on/off the electric heater 

 

MODE 

Switch unit running modes or save setting 

parameters 

 

TOUCH TIMING 

Touch timing settings 

 

 

HEATING 

MODE

 

The unit will start according to the water temperature and target temperature. The 
electric heater will not start immediately. After 200 minutes, the unit will judge if it has 
reached target temperature. If not, the electric heater will start. 

 

ECO HEATING 

MODE 

The heat pump system will start according to the water temperature and target 
temperature. The electric heater always will be off. 

 

INTELLIGENT 

MODE 

The unit will automatically judge the operation mode according to the ambient 
temperature. 

 

HIGH 

REQUIREMENT 

MODE 

The difference between heating mode and high requirement mode is the delay time of 
electric heater. In the high demand mode, the electric heater will start without delay, 
which can help the user to heat water quickly in a short time. 

 
 

 

VACATION 

MODE 

Enable Vacation mode 

 

SET TEMP 
REACHED 

Set temperature has been reached 
and the unit will shut off 
automatically 

 

FAN 

Fan is on 

 

HYDROBOOST 

The Hydroboost setting is on 

 

LOWER 

TANK TEMP 

Temperature of the lower tank 

 

DEFROST 

The unit is defrosting 

 

MINUTE 

Minute value is being set 

 

LOCK 

Keyboard is locked 

 

SECOND 

Second value is being set 

 

PARAMETER 

SETTING 

Parameter is adjustable 

 

WI-FI 

State of Wi-Fi connection 

*Only available as an optional upgrade

 

 

Содержание Evo315-C

Страница 1: ......

Страница 2: ...ller 7 6 2 Operating Functions 8 6 2 1 Startup Shutdown 8 6 2 2 Switching Modes 8 6 2 3 Locking the Controller 8 6 2 4 Setting Checking the Target Temperature 9 6 2 5 Hydroboost Setting 9 6 2 6 Force...

Страница 3: ...dvanced energy efficiency technologies and built in smart features to ensure you re provided with clean safe and economical hot water all year round Conforms to AS 3498 2009 Australia and New Zealand...

Страница 4: ...year d Press at any stage to cancel 3 Press until is displayed This will activate Eco Heating Heat Pump only mode and will provide the most efficient heating 4 During periods of unusually high hot wa...

Страница 5: ...you restart the unit or turn it on manually the unit will not start to run again for approximately 3 minutes This is a protection feature to safeguard the compressor The handle of the P T safety valv...

Страница 6: ...eat resistant and durable Piping for the P T Valve The spec of the valve connecting thread is BSP3 4 internal thread After installation confirm that the drainpipe outlet is exposed in the air When the...

Страница 7: ...nces to allow airflow to circulate through the unit it is advised to keep a minimum gap between walls fences etc of 1000mm on the air inlet outlet sides 300mm rear clearance 600mm overhead clearance W...

Страница 8: ...water temperature and target temperature The electric heater always will be off INTELLIGENT MODE The unit will automatically judge the operation mode according to the ambient temperature HIGH REQUIRE...

Страница 9: ...for 0 5 seconds in the running screen of the controller to turn the unit off The main display will now show OFF The unit will dim the screen and display the standby screen when the controller has not...

Страница 10: ...5 Hydroboost Setting Also known as the Electric heater the Hydroboost setting allows higher levels of hot water to be produced When there are high hot water usage requirements such as guests staying t...

Страница 11: ...ameter value as shown in the below table and press the key to open that value Change the value using the up down arrow keys and press the key to save changes Press to exit the menu Description Paramet...

Страница 12: ...t up time A and end time B Press to save the setting and exit back to the main interface Press and hold for 2 seconds the timer display will flash When the timer display flashes choose the start up ti...

Страница 13: ...sh when it is selected use the arrow keys to select your desired start day then press to save all changes and exit back to the main interface Note Format is mm dd Example The unit will start up on Sep...

Страница 14: ...rs E01 EEV adjustment mode 0 1 1 0 Manual 1 Auto E02 EEV target overheat temp 20 20 5 E03 EEV initial steps 0 500 240 E04 EEV minimum steps 0 500 80 E05 Defrosting EEV steps 0 500 480 System parameter...

Страница 15: ...sor shutdown ambient temp 1 30 90 65 R20 The compressor shutdown ambient temp 2 30 90 55 Timing parameters L01 Whether enable the vacation mode 0 1 0 0 Disable 1 Enable L02 The vacation mode Year 0 99...

Страница 16: ...p setting needs to be reduced if it is too high 4 Check the high pressure switch If the switch is open when the connection is closed replace it Low pressure protection E02 1 Check if the system is lea...

Страница 17: ...BRN BLU Y G 3G2 5mm L N L N N N N N N 1 3 2 4 5 6 7 8 01 N 4 WHT N 4V 1 2 3 4 MTS RESET 1 3 4 2 OUT1 OUT2 OUT3 OUT4 OUT5 AC N 3 4 3 4 CN5 OUT6 CN6 CN1 CN2 12V NET GND 485 A 485 B DI01 DI03 GND DI04 GN...

Страница 18: ...80900421 KP cover 640 22 ABS Black Gloss 9005 Plastic Absorption 14 80708081 KP Top Cover Galvanized sheet 0 8 gray white matte 9006 15 80704839 Fan top cover Galvanized sheet 1 0 Black finish 9005 16...

Страница 19: ...th the water heater 8 4 Using the Overheating Protector The overheating protector is used to turn the power off in an emergency or with power supply issues preventing the water from being heated too h...

Страница 20: ...clean of the unit with a damp cloth MAJOR FIVE YEAR SERVICE It is recommended a major five 5 year service be conducted on the Evo315 C Warning Servicing of a water heater must only be carried out by...

Страница 21: ...ed within the i Costs associated with delivery handling freighting or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 o...

Отзывы: