Evo315-C Manual
Page 14
Temperature parameters
R01
Hot water target temp setting value
38~75
55
R03
Heating, the lower temp return difference setting
value
1~20
5
R04
Whether enable the electric heater independent
setting value
0 / 1
0
0-Disable / 1-Enable
R05
Electric heating temp setting value
30~90
55
R06
Electric heat startup delay
0~450min
200min
R07
Whether the electric heater replace the
compressor
0 / 1
1
0-No / 1-Yes
R08
Electric heater replace the compressor ambient
temp
-20~10
-5
R09
Electric heater zero delay startup ambient temp
0~30
5
R10
Electric heater delay startup ambient temp
10~40
25
R12
The compressor force to shutdown temp
-30~-5
-15
R14
Replacement value of external heat source target
temperature
10~60
45
R15
The compressor limit temp under high ambient
temp
55~80
78
R17
Whether enable the top temp sensor for
controlling the compressor startup
0 / 1
0
0-Disable / 1-Enable
R18
Heating, the top temp return difference setting
value
1~20
1
R19
The compressor shutdown ambient temp 1
30~90
65
R20
The compressor shutdown ambient temp 2
30~90
55
Timing parameters
L01
Whether enable the vacation mode
0 / 1
0
0-Disable / 1-Enable
L02
The vacation mode: Year
0~99Y
0
L03
The vacation mode: Month
0~12M
0
L04
The vacation mode: Day
0~31D
0
L05
Whether enable the timing on/off function
0 / 1
0
0-Disable / 1-Enable
L06
Timing on period 1: Hour
0~23h
0
L07
Timing on period 1: Minute
0~59min
0
L08
Timing off period 1: Hour
0~23h
0
L09
Timing off period 1: Minute
0~59min
0
L10
Timing on period 2: Hour
0~23h
0
L11
Timing on period 2: Minute
0~59min
0
L12
Timing off period 2: Hour
0~23h
0
L13
Timing off period 2: Minute
0~59min
0
Switch status parameters
S01
Remote on/off switch
CL / OP
Close
S03
Low pressure protection switch
CL / OP
Close
S04
High pressure protection switch
CL / OP
Close
S05
Time-lapse signal switch
CL / OP
Open
S06
External setting switch
CL / OP
Open
Temperature status parameters
T01
Ambient temp
-30~93
/
T02
Water tank bottom temp
-30~93
/
T03
Water tank top temp
-30~93
/
T04
Coil temp
-30~93
/
T05
Suction temp
-30~93
/
T06
Solar control temp
-30~93
/
T10
App/wire controller display temp
-30~93
/
T20
Enter parameter over-range protection times
0~65535
/
T21
Memory chip EEPROM storage times
0~30000
/