![evoheat Evo315-C Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/evoheat/evo315-c/evo315-c_installation-and-operation-manual_2446582020.webp)
1300 859 933
www.evoheat.com.au
Evo315-C Manual
Page 19
9. Maintenance
Your Evo315-C will operate most efficiently if regularly inspected as part of your home maintenance schedule.
MINOR ANNUAL MAINTENANCE
It is recommended that the minor maintenance be performed every 12 months by the dwelling occupant.
The minor maintenance includes:
•
Operate the easing lever on the temperature pressure relief valve. It is very important you raise and lower the
lever gently. Exercise care to avoid any splashing of water, as water discharged from the drain line will be hot.
Stand clear of the drain lines point of discharge when operati
ng the valve’s lever.
•
Operate the easing level on the expansion control valve (if fitted). It is very important you raise and lower the
lever gently.
•
Conduct a visual inspection of all plumbing and electrical connections.
•
Check the condensate drain line to ensure it is not blocked.
•
Check that air vents are not blocked or obstructed, and if necessary clean with a damp cloth or air blower.
•
Conduct a general external clean of the unit with a damp cloth.
MAJOR FIVE-YEAR SERVICE
It is recommended a major five (5) year service be conducted on the Evo315-C.
Warning: Servicing of a water heater must only be carried out by qualified EvoHeat personnel.
Phone EvoHeat Service on 1300 859 933 for our closest Accredited Service Agent.
Note:
The five-year service and routine replacement of any components such as the anode and relief valve(s) are not
included in the EvoHeat warranty. Only genuine replacement parts should be used on this water heater.
The major service includes the following actions:
•
Replace the temperature limiting valve.
•
Replace the temperature pressure relief valve.
•
Inspect the anode and if required, replace the anode. If the anode is not replaced, it should be replaced within
three years of this service.
•
Check the heating cycle of the unit.
•
Visually check the unit for any potential problems.
•
Inspect the plumbing and electrical all connections.
•
Check the condensate on drain line to ensure it is not blocked.
Note
: The water heater may need to be drained during this service. After the completion of the service, the water
heater will take some time to reheat the water. Depending upon the power supply connect on, hot water may not be
available until the next day.
Содержание Evo315-C
Страница 1: ......