![evoheat Evo315-C Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/evoheat/evo315-c/evo315-c_installation-and-operation-manual_2446582011.webp)
1300 859 933
www.evoheat.com.au
Evo315-C Manual
Page 10
6.2.7 Sanitech System
The Sanitech feature’s purpose is to keep the water free of bacteria such as Legionella by heating the
tank water to 70°C for one 30-minute period every week at midnight.
An instance when you may want to alter the Sanitech function is if you have solar and would prefer the
Sanitech to run during the day, for example at 12pm, rather than midnight. You would need to change the
g03 parameter to 12 (12pm).
Press
and hold for 10 seconds a single time to access the parameter menus. When the screen displays ‘000’
press the up/down arrow keys until the number ‘0 ’ is displayed, then press the
key. Use the up/down arrow
keys to navigate to the correct parameter value as shown in the below table and press the
key to open that value.
Change the value using the up/down arrow keys and press the
key to save changes. Press
to exit the menu.
Description
Parameter
Default
Range
Changing these settings
may lower or disable the
unit’s ability to ensure your
water is free from bacteria
.
Sanitech Target Temperature
g01
70 degrees
30-70 degrees
Sanitech Temperature Hold Time
g02
30 minutes
0-90 minutes
Sanitech Start Time (24-hour clock)
g03
0 hours
0-23 hours
Sanitech Operation Cycle
g04
7 days
7-99 days
To disable the Sanitech feature, simply adjust the Sanitech target temperature (g01) to a figure below the normal
water storage temperature (generally 50 degrees or lower).
6.2.8 System Date & Time
In the standby or running interface, press
once, the hour digit will flash indicating it is being altered.
Press the
or
to change the hour setting, then press
to confirm. Repeat this to change the minute value.