APPENDIX - CONTROL COMPONENTS
A f f i n i t y 3 0 G e
Evo, Inc. | 8140 SW Nimbus Ave., Bldg 5 | Beaverton, Oregon 97008 USA
Phone 503.626.1802 | Fax 503.213.5869 | www.evoamerica.com | [email protected]
27
Pipe Size.......................................................................1/2”
Housing Material................................................Aluminum
Mounting..................................Suitable for multi-positional
mounting.
Certifi cations.....................................ANSI Z21.18/CSA 6.3
Gas Types.................Natural or liquefi ed petroleum gases
Maximum Inlet Pressure............................1/2 psi (3.4 kPa)
Emergency Exposure Limits....................2.5 psi (17.2 kPa)
Temperature Ranges................ 32° to 225°F (0° to 107°C)
Pressure Settings Natural Gas - NG ...........4” WC (Fixed)
Pressure Settings Propane Gas - LP..........10” WC (Fixed)
Evo
Affi nity 30Ge inlet gas pressure must not exceed 1/2 PSI (maximum) gas service. The Affi nity 30Ge utilizes a factory-set
internal gas regulator that accepts 1/2 PSI inlet pressure and outputs 4” W.C. for use by the burner system.
No adjustments to the internal regulator are necessary.
INTERNAL GAS REGULATOR SPECIFICATIONS