INSTALLATION INSTRUCTIONS
A f f i n i t y 3 0 G e
Evo, Inc. | 8140 SW Nimbus Ave., Bldg 5 | Beaverton, Oregon 97008 USA
Phone 503.626.1802 | Fax 503.213.5869 | www.evoamerica.com | [email protected]
18
CONNECTING TEMPERATURE SENSOR WIRE TO COOKING SURFACE
1
Inner Zone
2
Outer Zone
3
Outer Zone
4
Outer Zone
1
2
4
3
Place suitable
protection on drip
pan when tilting
cook surface
upward.
J-Hook Guide
Tube
(2 tubes)
J-Hook
(2 hooks)
TC Wire
(4 wires total)
STEP 8:
Place cook surface over circular skirt with the Rear Retaining Bullet facing opposite the front
control panel with the bullet resting on the chassis skirt.
STEP 9:
Connect TC wires as per diagram and tighten with supplied nuts to each weld-stud location.
POSITION THE COOKING SURFACE ON THE CHASSIS AND ANGLE IT UPWARD TO
PROVIDE ACCESS FOR CONNECTING THE TEMPERATURE SENSOR (TC) WIRES.
DO NOT OVER TIGHTEN TC-WIRE HEX NUTS. DOING SO WILL BREAK THREADED
WELD STUD ON COOK SURFACE.
WITH THE COOKING SURFACE SUPPORTED IN AN UPRIGHT POSITION, GENTLY PULL
EACH TC WIRE UP THROUGH ITS GUIDE TUBE AND ATTACH TO ITS RESPECTIVE
THREADED STUD LOCATION ON THE UNDERSIDE OF THE COOKING SURFACE.
TC Wire
Guide Tube
(4 tubes)
Rear Retaining
Bullet Slot
TC Sensor Location