EMV400S FHD / EMV400SSD Mobile DVR
153
events occurred during the SD card recording process will be ignored and not be recorded). Up
to four alarm events can be simultaneously recorded if the alarms are triggered at the same
time.
FTP Upload:
Check the box to enable uploading recordings to the FTP server function. To setup
the FTP server, please refer to
7.3.7.6 FTP
.
Send to Xfleet:
Check the box to send the alarm data to the Xfleet system. Note that for the
Xfleet system to receive alarm data from the mobile DVR in order to perform the alarm event
actions on Xfleet system, this function must be enabled.
FTP Upload File Type:
Select MP4 file type to upload videos to FTP server; select JPEG file type
to upload snapshots to the FTP server.
Alarm Output:
Select an alarm output number. When an alarm is triggered, the signal will be
transmitted through the selected alarm output relay.
Output Type:
Select an output type when an alarm is triggered.
Timeout: Select this option and then set up the Timeout Duration in the field below, the
alarm output will last for the setup duration time (1 ~ 150 seconds).
Permanent: Alarm will remain active until the user presses the “Enter” key on the IR
Remote Control or resets the alarm remotely.
Transparent: Alarm output remains as long as the alarm input is active.
Trans + Timeout: Alarm output continues until event ends, then continues for the setup
duration time (1 ~ 150 seconds).
Timeout Duration:
This function only appears when you select
Timeout
or
Trans + Timeout
options in the Output Type drop-down list. Select a duration time for the motion event. The
alarm output will last for the setup duration time between 1 and 150 seconds.
Main Monitor/Call Monitor:
Select
Full Screen
to force the camera associated with the
selected alarm number to display full screen on the monitor. The full screen camera view will
last according to the Output Type selected in the field above.
Record:
Select a camera to start recording when the associated alarm number is triggered.
Input Type:
Select an input type when the selected alarm number is triggered. The options
include N.O. and N.C.
Active Camera:
This function is for associating an alarm trigger with a specific camera. For
example, if you set up an external motion detector near Camera 2, you can select Camera 2 in
this field. The alarm will be associated with this camera for full screen display, event logging
and PTZ actions.
PTZ:
If the Active Camera selected above is a PTZ camera, you can further set up the PTZ
actions in this field.
The following time synchronization function must work with the radio-controller clock.
Time Sync Enable:
Check to enable the time synchronization with the connected radio-
controlled clock.
Time Sync Interval:
Select a time sync interval time (by hour) for the MDVR to synchronize the
time with the radio-controlled clock.