Before input the data, you have to execute the smoke index measurements. You can input up to 3 values; the analyzer
will make the average calculations.
These values will be printed on report with the other gas analysis data.
Press the [
MENU
] key until the following page will be displayed:
Press
[
ENTER
] to input the smoke index values.
Change the value of 1th test by pressing the [
S
] and [
T
] keys. Press the [
ENTER
] key to store the value and input
the test 2 value.
Change the value of 2th test by pressing the [
S
] and [
T
] keys. Press the [
ENTER
] key to store the value and input
the test 3 value.
Change the value of 3th test by pressing the [
S
] and [
T
] keys.
Press the [
ENTER
] key to store the value.
Press the [
S
] key to change the fuel specification.
Press the [
ENTER
] key to store the value.
Press
[
ESC
] to return to the measure page.
6.3
Analysis Data Print
The 2000 series
has two different possibilities to print the flue gas analysis data. You can use the optional internal
impact printer or the standard IR port for your HP 82240B wireless thermal printer.
6.3.1 Built-In
Printer
(option)
You can order the
the 2000 series
complete with an internal 24 column impact printer. The printer is integrated with the
instrument and the power is supplied by the same batteries as the analyzer. The impact model gives you one more
advantage: more readability and long time duration on your documents.