Operating Instructions
Safety System MGBS-P-L.-AP…
24
(translation of the original operating instructions) 2527245-02-01/22
11.9. Connection of MGBS-AP
Connect the device as shown in
. The monitoring outputs can be routed to a control system.
The following applies to devices with RST input
: The switches can be reset using the RST input. To do this, a voltage
of 24 V is applied to the RST input for at least 3 s. The RST input must be connected to 0 V if it is not used.
WARNING
In the event of a fault, loss of the safety function due to incorrect connection.
Ì
To ensure safety, both safety outputs (FO1A and FO1B) must always be evaluated.
Important!
Ì
The example shows only an excerpt that is relevant for the connection of the MGBS system. The
example illustrated here does not show complete system planning. The user is responsible for safe
integration into the overall system. Detailed application examples can be found at www.euchner.com.
Simply enter the order number of your switch in the search box. You will find all available connection
examples for the device in
Downloads
.
Connected load
Safety Outputs
Door
Monitoring
Read Head
Actuator
Monitoring Outputs
FO1B
4
OI
5
Diagnostic
-B1
UB
2
IMP
1
IMM
8
0 V
UB
7
OD
6
FO1A
3
MGBS
1
2
-F1
1
2
-F2
13
14
-S1
24V DC
0 V
24V DC
0 V
Fig. 4:
Connection example, version with plug connector M23