Number Axis Parameter Description
Range [Unit]
Acc.
236
CL actual target
current scale
factor
Actual target value of the current scale factor
as defined by axis parameters 113, 114, 116,
and 117. Due to the configurable delays using
axis parameters 120 and 121, the actual target
current scale factor may be different to the
actual current scale factor.
0… 255
[1/256]
R
237
Position error
This parameter indicates the difference
between the virtual actual position of the
ramp generator and the measured position of
the motor.
−2.147.483.648…
+2.147.483.647
[µsteps]
[encoder steps]
R
7.1
Velocity Calculation
Some axis parameters are related to the speed of the motor. The unit of the velocity
<value>
is pulse per
second (pps). For calculating the speed it is necessary to set the microstep resolution of the driver (axis
parameter 140) first. Further, the fullsteps of the motor must be given. Now, calculate as follows: