TMCM-1310 TMCL Firmware V1.11 Manual (Rev. 1.16 / 2014-MAR-19)
63
www.trinamic.com
6.8.39
TMCL Control Functions
There are several TMCL control functions, but for the user are only 136 and 137 interesting. Other control
functions can be used with axis parameters.
Instruction number
Type
Command
Description
136
0 – string
1 – binary
Firmware version
Get the module type and firmware revision as a
string or in binary format. (
Motor/Bank
and
Value
are ignored.)
137
don’t care Reset to factory
defaults
Reset all settings stored in the EEPROM to their
factory defaults
This command does not send back a reply.
Value must be 1234
S
PECIAL REPLY FORMAT OF COMMAND
136
Type set to 0 - reply as a string:
Byte index Contents
1
Host Address
2… 9
Version string (8 characters, e.g. 1310V102)
There is no checksum in this reply format!
Type set to 1 - version number in binary format:
Please use the normal reply format. The version number is output in the
value
field of the reply in the
following way:
Byte index in value field Contents
1
05
2
1E
3
Version number, low byte
4
Version number, high byte