Axis Parameters
The following sections describe all axis parameters that can be used with the SAP, GAP, AAP, STAP and
RSAP commands.
Attention!
Related to positioning, there are parameters which have two unit specifications.
- In
open loop mode
, calculate with
µsteps
.
- In closed loop mode, calculate with encoder steps.
For further information about closed loop operation parameters and functions please refer to Section 9.
M
EANING OF THE LETTERS IN COLUMN
A
CCESS
:
Access
type
Related
command(s)
Description
R
GAP
Parameter readable
W
SAP, AAP
Parameter writable
E
STAP, RSAP
Parameter automatically restored from EEPROM after reset or power-on. These
parameters can be stored permanently in EEPROM using STAP command and
also explicitly restored (copied back from EEPROM into RAM) using RSAP.
Basic parameters should be adjusted to motor / application for proper module operation.
Parameters for the more experienced user
–
please do not change unless you are absolutely
sure!
Parameters for closed loop operation
Number Axis Parameter Description
Range [Unit]
Acc.
0
Target position
The desired position in position mode (see
ramp mode, no. 138).
−2.147.483.648…
+2.147.483.647
[µsteps]
[encoder steps]
RW
1
Actual position
The current position of the motor. Should
only be overwritten for reference point
setting.
−2.147.483.648…
+2.147.483.647
[µsteps]
[encoder steps]
RW
2
Target speed
The desired speed in velocity mode (see ramp
mode / axis parameter 138).
In position mode, this parameter is set by
hardware:
-
during acceleration to maximum speed
-
during deceleration and rest to zero
-327.678.000…
+327.679.999
[pps]
RW
3
Actual speed
The current rotation speed.
-327.678.000…
+327.679.999
[pps]
RW
4
Maximum
positioning
speed
Should not exceed the physically highest
possible value.
0… +327.679.999
[pps]
RWE
5
Maximum
acceleration
The limit for acceleration (and deceleration).
1… +24.999.998
[pps/s]
RWE