TMCM-1310 TMCL Firmware V1.11 Manual (Rev. 1.16 / 2014-MAR-19)
91
www.trinamic.com
Number Axis parameter
Description
Units / Default
Acc.
121
CL current scale
decrement
timeout
This parameter defines the delay between two
current scale factor decrements and thereby
controls the rate at which the current scale
factor will be decreased, e.g., in order to
prevent from oscillations around the target
position.
Setting a timeout value here serves for
dampening
and
prevents
from
high
oscillations.
0 = the scale factor will directly be set to the
actual target value without delay.
Default = 1
[ms]
RW
122
CL current scale
enable
1 = current scaling function on for closed loop
0 = current scaling function off, closed loop
operation is still possible
The current scaling functionality can be
switched off if full specified current amplitude
shall be used all the time.
When switched on, the current scaling
functionality adapts the current according to
the configured profile. This saves energy and
keeps the motor cooler.
Default = 1
RW
123
CL actual current
scale factor
Actual value of the current scale factor.
0… 255
[1/256]
R
236
CL actual target
current scale
factor
Actual target value of the current scale factor
as defined by axis parameters 113, 114, 116,
and 117. Due to the configurable delays using
axis parameters 120 and 121, the actual target
current scale factor may be different to the
actual current scale factor.
0… 255
[1/256]