background image

User Manual

SLEIPNER AS

P.O. Box 519
N-1612  Fredrikstad
Norway
www.sleipnergroup.com

DOCUMENT ID:

REVISION:

DATE:

LANGUAGE:

To download your language go to www.sleipnergroup.com

2917
14

Keep this

manual onboar

d!

2020

EN

Including Installation For Control Panels

PJC211 & PJC212

U M I  M

Содержание PJC211

Страница 1: ...rikstad Norway www sleipnergroup com DOCUMENT ID REVISION DATE LANGUAGE To download your language go to www sleipnergroup com 2917 14 K e e p t h i s m a n u a l o n b o a r d 2020 EN Including Instal...

Страница 2: ...up 10 Hold Calibration 11 Joystick Calibration 11 Menu System Information 11 Information PPC SR150000 SR61242 11 Information PDC101 PDC201 12 Information PDC301 12 Panel Information 12 S Link Diagnost...

Страница 3: ...the same time the thruster will not run If both are operated in the same direction the thruster will run in this direction If you notice any faults with the thruster switch it off to avoid further da...

Страница 4: ...ss both ON buttons simultaneously to activate control panel Information display see following pages for details Speed control joystick for bow thruster Speed control joystick for stern thruster Inform...

Страница 5: ...rn thruster installation Bow and stern thruster installation Activating the bow thruster Control panel example Control panel example Control panel example Activating the stern thruster Activating both...

Страница 6: ...n not be operated to auto setup is completed OR RUN SETUP DEVICES IN CONFLICT Detected devices in conflict Two or more thrusters de ned as same instance bow stern bow STB Stern STB Run Setup procedure...

Страница 7: ...ERN BOW STB STERN STB BOW or STERN in a conventional thruster system In a system with two bow or stern thrusters i e a catamaran BOW and STERN is port thruster BOW STB and STERN STB is starboard thrus...

Страница 8: ...tween Normal and Inverted running direction for the thruster Function Values SAC default SRAC Setup the control unit behaviour SAC Tunnel speed thruster SRAC SAC with SR150000 retract controller SR150...

Страница 9: ...o the hydraulic controller are shown at the left side in display and thruster s at the right side of the display Direction Values Normal default Inverted Switches between Normal and Inverted running d...

Страница 10: ...r system In a system with two bow or stern thrusters i e a catamaran use BOW or STERN for port thruster BOW STB or STERN STB for starboard thruster Thrust Values 0 100 Default 70 Set the amount of thr...

Страница 11: ...devices found can ll more than one screen A scroll bar indicates the position of the selected item The joystick s operates the thrusters as normal while info is displayed This will be useful for troub...

Страница 12: ...Count Receive error counter Error during reception increments the value After every successful reception the value is decremented Tx Error Count Transmit error counter Error during transmit increments...

Страница 13: ...lues CELSIUS Default FAHRENHEIT Set the panel temperature displaying unit WHEN RETRACT IS OUT Values NO WARNING Default WARNING EVERY 10sec Select WARNING EVERY 10sec for external buzzer or lamp warni...

Страница 14: ...t Alarm Description pages in the Auto Reset column you can see which alarms that are auto reset SPECIFIC ALARMS STOP BUTTON Pressing the STOP button on a hydraulic panel will activate the dump valve a...

Страница 15: ...hown in a dual stern thruster setup Battery indicator will be shown here in a single DC electric stern thruster setup BOW STERN BOW STB STERN STB Examples of display view for different panels applicat...

Страница 16: ...F to 130 C 266 F Symbol shown when a DC Thruster is used in a dual bow or dual stern setup Proportional Thruster Display Symbols MC_0053 Thrust power and direction Bow thruster s Input from bow joysti...

Страница 17: ...oltage below 8 5V 15V 12V 24V system Temperature above 110 o C 230 o F None 4 Red backlight in display and continuous short beeps If one or more of the thrusters enters an alarm state Voltage below 8...

Страница 18: ...anguage English Backlight Level 5 Backlight Night Colour Green Backlight Nightlevel 1 Timer Auto Off 05 min Hold Calibration 70 Bow and Stern All system devices will be erased from memory Setup proced...

Страница 19: ...2 3 Motor relay fault Turn off thruster battery main switch Thruster must be serviced by authorized personnel 8 Critical Error 2 3 PPC output fail PPC must be sent for service 9 Low Motor Current 2 3...

Страница 20: ...2 3 Any Stabilizer alarm See stabilizer panel for more info 28 AC Motor Overtemp Yes 1 2 3 Hydraulic AC motor power pack overtemp Higher than 120 C 248 F Stop running and wait for temperature to drop...

Страница 21: ...essure parameter 0104 10503 0 16 PHC System Pressure Short Circuit System pressure sensor short circuit Wires shorted or sensor defective check wiring sensor Replace sensor 10504 0 13 PHC AI 1 Open Ci...

Страница 22: ...ECI Cooling Pump Undervoltage ECI cooling pump under voltage voltage is lower than 18 0V Check PHC 3 input voltage is higher than 18 0V Replace ECI cooling pump 10524 0 55 PHC ECI Cooling Pump Overte...

Страница 23: ...cient troubleshooting if necessary The installer must read this document to ensure necessary familiarity with the product before installation Instructions in this document cannot be guaranteed to com...

Страница 24: ...cut out is jagged or chipped use a sealant to assist the gasket 3 Place the gasket to the back face of the panel 4 Plug cables into the connectors at the rear of the control panel 5 Insert the contro...

Страница 25: ...Panel Height 141 5 55 141 5 55 W Panel width 83 3 3 83 3 3 a Raised height above the dashboard 65 66 2 6 65 66 2 6 b Depth behind the dashboard not inc cables 31 8 1 25 31 8 1 25 c Panel screw hole d...

Страница 26: ...imum Units Comment Input voltage 9 31 Volt DC Powered from S Link Current Voltage 20 120 mA External Alarm Buzzer Voltage 31 Volt DC External Alarm Buzzer Current 500 mA Internally fused Technical Spe...

Страница 27: ...shall be connected to GND and the red wire connected to 12VDC or 24VDC To reduce the risk of interference avoid routing the S Link cables close to equipment such as radio transmitters antennas or high...

Страница 28: ...black red B B 05M 05M 5A 12 24 5A 12 24 PPC PJC 212 Proportional joystick control panel Bow and stern Station 1 S PJC 212 Observe PPC battery terminal polarity S S 12 24V 5A S link on off switch red...

Страница 29: ...Serial number ie Thruster AMS PPC etc Bow Bow STB Stern Stern STB Fill in the type location and serial numbers of the S link devices installed Keeping this as a reference will make the setup procedur...

Страница 30: ...ned to the Purchaser at the Warrantor s expense If on the other hand the claim is determined to result from circumstances such as described in section 4 above or a result of wear and tear exceeding th...

Страница 31: ...31 2917 14 2020 PJC 211 212 MC_0037 Notes...

Страница 32: ...accuracies or omissions it may contain Continuous product improvement may change the product speci cations without notice Therefore Sleipner Motor AS can not accept liability for any possible differen...

Отзывы: