Program Mode
Echo Program Mode is used to adjust which Echo Presets are controlled by wireless inputs as well as which
Echo Zones are associated with wireless outputs.
Enter Program Mode by pressing and holding the [RECORD/PROGRAM MODE] button for three seconds.
When in Program Mode, press the [ON] and [OFF] buttons to increment or decrement values.
The OUTPUT STATUS LEDs display the current value edited with [ON] and [OFF] buttons:
• 2 green LED’s indicate Preset 2 for the selected Echoflex input.
• When the selected wireless input configured Preset is greater than 10, the additional Preset number
will indicate additively in a cycle. First, all LED’s will indicate (=10), then the remaining LED’s indicate
(up to 6), followed by a long pause.
Assigning Echo Presets to Wireless Inputs
The Preset number associated with the selected wireless input is displayed on the OUTPUT STATUS LED's,
where the number of LEDs lit is the Preset number value. This Preset defines the lights on action of the
linked Echoflex devices. See
Manual Control of Wireless Inputs
for more information about each
Echoflex device type and it's behaviors with Preset actions.
By factory default, the four Echoflex Inputs are configured to Preset 1 through Preset 4, respectively. Presets
1-16 may be individually assigned to the wireless inputs.
Configure Preset
1:
Place the EEI in Program Mode.
2:
Press the [SELECT] button until the wireless input to be configured is selected. The current preset
number configured to the selection displays on the OUTPUT STATUS LED's.
3:
Press the [ON] button to increase the preset number or press the [OFF] button to decrease the Preset
number. When the Preset number is greater than 10, a second set of LED's will indicate as an additive
process.
4:
When the desired preset number for the selection is displayed, you can choose to:
a: Press the [SELECT] button to change the selection to the next Echoflex Input and repeat the
process of configuring the preset number for the selection.
b: Exit Program Mode by pressing the [RECORD/PROGRAM] button.
5:
Press the [RECORD/PROGRAM] button to save the selection and exit Program Mode. The selected
Echoflex Input or Echoflex Output LED will blink to indicate the save process.
Note:
This behavior ONLY occurs while you are in ECHO Program Mode for the given Echoflex
Input
Note:
Program Mode times out after 90 seconds of inactivity. Any changes that were made
before the timeout will not be saved. To exit Program Mode with changes saved, press
the [RECORD/PROGRAM] button.
Note: