E-SL 450BD Series Instruction Manual
First Run
13
This is our recommended procedure to run the gate for the first time.
PUSH 1 or PUSH 2 to increase or decrease the parameter. Then press SET button to move to the
next parameter.
1.
Press SET button to begin.
2.
LED shows P1: Press Push 1 to get P1 setting to 30.
3.
Press SET button.
4.
LED shows P2: Press Push 1 to get P2 setting to 10.
5.
Press SET button.
6.
LED shows P3: Press Push 1 to get P3 setting to 30.
7.
Press SET button.
8.
LED shows P4: Press Push 1 to get P4 setting to 3.
9.
Press SET button.
10.
LED shows P5: Press Push 1 to get P5 setting to 2.
11.
Press SET button.
12.
LED shows P6: Press Push 1 to get P6 setting to 10.
13.
Press SET to finish. You should hear 3 beeps; this indicates parameter
programming is finished.
Manually unlock the gate, then move it half-way and re-engage. Activate using Push 1 button (as
shown above) The gate should run open. Press Push 1 again and it should run closed. The gate is now
set up for regular usage.