E-SL 450BD Series Instruction Manual
Control Board Overview
16
CAUTION! Do not run 110V AC power direct to the board. This will cause
permanent damage to both boards and void your warranty. Caution!
Gate Opener reactions to signals:
PUSH1 and Receiver (PUSH 1 terminal, PUSH 1 button, 6 Prong Receiver):
Details:
•
Will activate gate with momentary contact (momentary contact between
PUSH1 and V+) or if you momentarily press the PUSH1 button.
•
Controls both leaves in 2 leaf mode (Dip switch 2 in the ON position).
•
Acts as party mode control to suspend auto-reclose by activating while
counting down auto-reclose in the open position.
Operational Sequence for terminal with auto-close ON (Dip switch 1 in on position):
1.
In closed position - momentary contact will open gates.
2.
When opening - momentary contact will stop gates and then it will auto reclose.
3.
When stopped mid cycle waiting auto reclose - momentary contact will move the gate in the
direc-tion opposite what it was moving before stopped.
4.
When open and counting auto-reclose pause time - momentary contact will stop pause time.
5.
Stopped in open position from override of auto-reclose from PUSH1 or Receiver -
momentary contact will reactivate pause time and close gate.
6.
When closing - momentary contact will stop the gate and then it will auto reclose.
Operational Sequence for terminal with auto-close OFF (Dip switch 1 in off position):
1.
In closed position - momentary contact will open gates.
2.
When opening - momentary contact will stop gates.
3.
When stopped mid cycle - momentary contact will move the gate in the direction
opposite what it was moving before stopped.
4.
When open - momentary contact will close gates.
5.
When closing - momentary contact will stop the gate.
6.
When stopped mid cycle - momentary contact will open the gate.
7.
When open with auto-reclose off - momentary contact will have no effect.
8.
When closing - momentary contact will re-open the gate.