Keypad Connector Diagram
YELLOW- Anti Tailgate
If not used, this must be connected to BLACK.
By adding a door
monitor switch between YELLOW and BLACK the door will relock
immediately after opening. If Output B is set up as Internal Alarm,
this switch will trigger the alarm if the door is opened without a
code or if the door is left open longer than the Door Ajar Time
setting.
RED, BLACK, GREEN, VIOLET, GRAY, ORANGE and SHIELD-
These wires all connect to the ERM module.
CONFIGURATION
PINS- “CONFIG”
YELLOW- Door Monitor
(Do NOT apply voltage)
GRAY*
SHIELD*
BLACK*- Ground
ORANGE*- Program (Do NOT
apply voltage)
VIOLET*
RED*- Input Voltage
GREEN*- Output for Encoded
Relay Module (optional)
*Connect to ERM inputs.
NOTE: The 2x6 connector is rotated 180 degrees
VOLTAGE SELECT
(Do NOT apply voltage)
12-24V (default)- Jumper on
one pin only
5V- Jumper on both pins