9
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
4.
Once the Keypad is in configuration mode, enter 0099#. The
Keypad will beep twice and both LEDS will flash for approxi-
mately 10 seconds. (During this time, the Keypad will appear
dead. Do NOT remove power!)
5.
Enter 98 followed by #. You should hear 3 beeps indicating
successful configuration (the RED LED will continue to flash
and the GREEN LED will be solid). If you hear a long error
beep, re-enter 98 followed by #. To change the audible beep
or illumination, proceed as follows. Otherwise, go to step 6.
a.
To change the audible beep, enter the code as follows:
Code
Audible Beep
201 #
Normal Beep (factory default)
200 #
Short Click (quieter)
b.
To change the illumination on the K1-26 only, enter the
code as follows:
Code Standby Mode
Normal Operation
210 # Off (factory default) Off (factory default)
211 #
Off
Dim
212 # Off
Bright
213 # Dim
Dim
214 # Dim
Bright
6.
Remove power.
7.
Remove configuration jumper.
8.
Re-apply power.
9.
Press PROGRAM button in the ERM to establish the encoded
connection. This will put the system into setup mode.
10. Press * * to exit.