10. LED INDICATORS
The possible LED combinations and their meanings are:
0 = LED OFF
1 = LED ON
2 = LED flashing slowly
3 = LED flashing quickly
MAN/
FAULT
BACKWASH
Plus
Plus
Plus
Plus
FILTRATION
Plus
Plus
Plus
Plus
0
0
1
0
1
0
0
1
1
1
0
1
1
1
0
1
1
1
2
0
0
3
3
3
(...together ...)
3
0
1
3
1
0
3
1
1
2
1
2
2
1
1
12
The possible LED combinations and their meanings are:
Equipment status
Functions
Filtration Plus
function in Remote mode.
Backwash Plus
function in Remote mode.
Mixed Cycle function in Remote mode. Motor at 100%.
Filtration Plus
function in Manual mode.
Backwash Plus
function in Manual mode.
Mixed Cycle function in Manual mode.
“Standby" mode. The equipment has power, motor stopped.
a) Valve in intermediate positions or position 6 in Remote mode.
b) Stop function in Manual mode.
c) Timer OFF position.
Configuration
Initial configuration: standing by for link with
ControlSystem
Filtration Plus
speed setting.
Backwash Plus
speed setting.
Mixed Cycle speed setting.
Errors
No water error. Start-up retry attempted.
No water error. Full shut-down.
EN
ode. Motor at 100%.
“Standby" mode. The equipment has power, motor stopped.
or position 6 in Remote mode.
ontrolSystem